My thought is you would want to get the data written somewhere (local PC file perhaps) as FAST as possible.
Then you could have a background app that's writing the transactions to the iSeries at a slower pace unless you need the iSeries app to have real-time interaction.
If it's TCP/IP based you could use Sockets programming.
If you decide to outsource any of the development let me know. We have written similar apps before but have not worked with your particular PLC.
Usually the idea is to offload the PLC the device transactions as quickly as possible.
Let us know the ultimate outcome.
Regards,
Richard Schoen
RJS Software Systems Inc.
Where Information Meets Innovation
Document Management, Workflow, Report Delivery, Forms and Business Intelligence
Email: richard@xxxxxxxxxxxxxxx
Web Site:
http://www.rjssoftware.com
Tel: (952) 736-5800
Fax: (952) 736-5801
Toll Free: (888) RJSSOFT
------------------------------
message: 2
date: Thu, 10 May 2012 09:10:09 -0400
from: Brian Piotrowski <bpiotrowski@xxxxxxxxxxxxxxx>
subject: Mitsubishi PLC interface to AS400 Data Tables
Hi All,
One of our assembly divisions recently acquired a Mitsubishi PLC module that they would like to connect to our AS400. They sent me the manual and it is an absolute nightmare to try and understand how the two systems are supposed to communicate. There's a lot of talk on triggers, local transports, etc., etc. It looks like a really powerful system, but I am having a very hard time interpreting what needs to be done from the manual.
The model number of the interface they purchased is QJ71MES96IT. They also purchased the transport/database module part number MESITTRNSDB2 to compliment the MES IT interface.
So my question is (and yes, it is a very broad question as I really do not have a starting point) - how do I get the data from the PLC into an AS400 table? Does anyone have any experience with this module that can help me understand how this is accomplished?
Any ideas, or resources I might be able to access to help me understand?
Thankee-sai!
/b;
-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-
Brian Piotrowski
Assistant Mgr. - I.T.
Simcoe Parts Service, Inc.
Ph: 705-435-7814 x343
Fx: 705-435-5029
-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-
http://www.simcoeparts.com
Please consider the environment. Don't print this e-mail unless you really need to.