× The internal search function is temporarily non-functional. The current search engine is no longer viable and we are researching alternatives.
As a stop gap measure, we are using Google's custom search engine service.
If you know of an easy to use, open source, search engine ... please contact support@midrange.com.



My thought is you would want to get the data written somewhere (local PC file perhaps) as FAST as possible.

Then you could have a background app that's writing the transactions to the iSeries at a slower pace unless you need the iSeries app to have real-time interaction.

If it's TCP/IP based you could use Sockets programming.

If you decide to outsource any of the development let me know. We have written similar apps before but have not worked with your particular PLC.

Usually the idea is to offload the PLC the device transactions as quickly as possible.

Let us know the ultimate outcome.

Regards,
Richard Schoen
RJS Software Systems Inc.
Where Information Meets Innovation
Document Management, Workflow, Report Delivery, Forms and Business Intelligence
Email: richard@xxxxxxxxxxxxxxx
Web Site: http://www.rjssoftware.com
Tel: (952) 736-5800
Fax: (952) 736-5801
Toll Free: (888) RJSSOFT
------------------------------

message: 2
date: Thu, 10 May 2012 09:10:09 -0400
from: Brian Piotrowski <bpiotrowski@xxxxxxxxxxxxxxx>
subject: Mitsubishi PLC interface to AS400 Data Tables

Hi All,

One of our assembly divisions recently acquired a Mitsubishi PLC module that they would like to connect to our AS400. They sent me the manual and it is an absolute nightmare to try and understand how the two systems are supposed to communicate. There's a lot of talk on triggers, local transports, etc., etc. It looks like a really powerful system, but I am having a very hard time interpreting what needs to be done from the manual.

The model number of the interface they purchased is QJ71MES96IT. They also purchased the transport/database module part number MESITTRNSDB2 to compliment the MES IT interface.

So my question is (and yes, it is a very broad question as I really do not have a starting point) - how do I get the data from the PLC into an AS400 table? Does anyone have any experience with this module that can help me understand how this is accomplished?

Any ideas, or resources I might be able to access to help me understand?

Thankee-sai!

/b;

-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-
Brian Piotrowski
Assistant Mgr. - I.T.
Simcoe Parts Service, Inc.
Ph: 705-435-7814 x343
Fx: 705-435-5029
-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-
http://www.simcoeparts.com

Please consider the environment. Don't print this e-mail unless you really need to.

The information contained in this communication is confidential and intended only for the use of those to whom it is addressed. If you have received this communication in error, please notify me by telephone (collect if necessary) and delete or destroy any copies of it. Thank you!



As an Amazon Associate we earn from qualifying purchases.

This thread ...

Follow-Ups:

Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].

Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.