Matt: On Wed, 27 February 2002, "Matt Patee" wrote: > I set this system value to IPL the box (which was double checked to be in > normal mode) at 10pm last night. Because this is the first time I've tried > this, I double checked the sytstem at 10:30pm and it's a good thing I did. > It did not IPL and the sysval was reset back to *NONE. Sign on with any profile that has at least *USE authority to *PGM QSYS/QWCCRTEC and call it from a command line. This will create a service dump 'report' of the dates/times of all phases of the previous IPL, telling you at least whether the system believes it IPLed at the given date/time. For a simple writeup of this program: http://makeashorterlink.com/?L1772087 or: http://www-912.ibm.com/s_dir/SLKBase.nsf/1ac66549a21402188625680b0002037e/11b0962b782a1b6d862566c90076bb1a?OpenDocument&Highlight=0,QWCCRTEC >From the symptoms you report, it does look like the IPL happened. Tom Liotta -- Tom Liotta The PowerTech Group, Inc. 19426 68th Avenue South Kent, WA 98032 Phone 253-872-7788 Fax 253-872-7904 http://www.400Security.com ___________________________________________________ The ALL NEW CS2000 from CompuServe Better! Faster! More Powerful! 250 FREE hours! Sign-on Now! http://www.compuserve.com/trycsrv/cs2000/webmail/
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.