Good News Everybody!

The new search engine is LIVE!

Please report any problems to david (at) midrange.com.




an alternate way to check on the lastipl is to use the following code.
It will check the start date/time of the SCPF job.

 PGM        /* Get the Date/Time the SCPF job starts */

 DCL        VAR(&DATA) TYPE(*CHAR) LEN(150) /* +
              Return Data */
 DCL        VAR(&BIN) TYPE(*CHAR) LEN(4) +
              VALUE(X'00000096') /* Len Return Data +
              (hex) */
 DCL        VAR(&CEN) TYPE(*CHAR) LEN(1) VALUE('Century +
              Code')
 DCL        VAR(&YY) TYPE(*CHAR) LEN(2) /*    YEAR  */
 DCL        VAR(&MM) TYPE(*CHAR) LEN(2) /*    MONTH  */
 DCL        VAR(&DD) TYPE(*CHAR) LEN(2) /* Day */
 DCL        VAR(&HH) TYPE(*CHAR) LEN(2) /* Hour */
 DCL        VAR(&M) TYPE(*CHAR) LEN(2) /* Minute */
 DCL        VAR(&SS) TYPE(*CHAR) LEN(2) /* Second */
 DCL        VAR(&FMT) TYPE(*CHAR) LEN(8) +
              VALUE('JOBI0400') /* Format for API */
 DCL        VAR(&JOB) TYPE(*CHAR) LEN(26) +
              VALUE('SCPF      QSYS      000000') /* +
              SCPF job */
 DCL        VAR(&JOBI) TYPE(*CHAR) LEN(16) /* Not needed */

 CALL       PGM(QUSRJOBI) PARM(&DATA &BIN &FMT &JOB +
                           &JOBI) /* Call the API to return the Job +
                           Attributes */

 /*   SUBSTRING THE RETURNED DATA INTO THE VARIABLES           */

              CHGVAR     VAR(&CEN) VALUE(%SST(&DATA 63 1))
              CHGVAR     VAR(&YY) VALUE(%SST(&DATA 64 2))
              CHGVAR     VAR(&MM) VALUE(%SST(&DATA 66 2))
              CHGVAR     VAR(&DD) VALUE(%SST(&DATA 68 2))
              CHGVAR     VAR(&HH) VALUE(%SST(&DATA 70 2))
              CHGVAR     VAR(&M ) VALUE(%SST(&DATA 72 2))
              CHGVAR     VAR(&SS) VALUE(%SST(&DATA 74 2))

 /*  SEND MESSAGE TO THE WORKSTATION'S MESSAGE AREA    */

              SNDPGMMSG  MSG('The system was last IPL''d on ' || &MM +
                           || '/' || &DD || '/' || &YY || ' at ' || +
                           &HH || ':' || &M || ':' || &SS || '.')

  END:        ENDPGM


-------------------------
 Bryan Dietz
3X Corporation

=========================================
> I set this system value to IPL the box (which was double checked to be in
> normal mode) at 10pm last night. Because this is the first time I've
tried
> this, I double checked the sytstem at 10:30pm and it's a good thing I
did.
> It did not IPL and the sysval was reset back to *NONE.

Sign on with any profile that has at least *USE authority to *PGM
QSYS/QWCCRTEC and call it from a command line. This will create a service
dump 'report' of the dates/times of all phases of the previous IPL, telling
you at least whether the system believes it IPLed at the given date/time.





As an Amazon Associate we earn from qualifying purchases.

This thread ...


Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2026 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].

Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.