Matt: On Wed, 27 February 2002, "Matt Patee" wrote: > I'm positive it didn't IPL. I'm positive that the SYSVAL was set properly. > I checked the history log from 5 minutes prior to the schedule until the > time I manually IPL'ed and did not find any reference to an attempted or > failed IPL of the system Ah, I suspect that's the problem. If your system was running "5 minutes prior", then an IPL wasn't possible and the system value was simply reset to *NONE when the time passed. Note that "IPL" is only the startup side of things, separate from the power-down side. Without a corresponding PWRDWNSYS, an IPL can't happen. See the Work Management guide for details. Tom Liotta -- Tom Liotta The PowerTech Group, Inc. 19426 68th Avenue South Kent, WA 98032 Phone 253-872-7788 Fax 253-872-7904 http://www.400Security.com ___________________________________________________ The ALL NEW CS2000 from CompuServe Better! Faster! More Powerful! 250 FREE hours! Sign-on Now! http://www.compuserve.com/trycsrv/cs2000/webmail/
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].