Trevor,
In V5R4M5 of LIC there were some incompatibilities at the LIC level, that
were later fixed by PTF.
Al
Al Barsa, Jr.
Barsa Consulting Group, LLC
400>390
"i" comes before "p", "x" and "z"
e gads
Our system's had more names than Elizabeth Taylor!
914-251-1234
914-251-9406 fax
http://www.barsaconsulting.com
http://www.taatool.com
http://www.as400connection.com
Trevor Perry
<trevor@xxxxxxxxx
m> To
Sent by: Midrange Systems Technical
midrange-l-bounce Discussion
s@xxxxxxxxxxxx <midrange-l@xxxxxxxxxxxx>
cc
10/19/2007 09:49 Subject
AM SAVRSTLIB problem
Please respond to
Midrange Systems
Technical
Discussion
<midrange-l@midra
nge.com>
I checked the archives, and there was no answer to help me, so here goes...
I have a 520 and a 515. I have configured AnyNet and can STRPASTHR both
ways. I am attempting SAVRSTLIB from the 520 pushing to the 515. I have
checked my Communication Entries, and tested with the user as *NONE, as
QUSER (which I think was installed when ObjectConnect was installed), and
also as *SYS.
Yet, I still get this error on the 520:
~~~~~~~~~~~~~~~~~~~~
Message . . . . : Communications failure. Session was not started.
Cause . . . . . : The system has detected a communications failure. The
sense code is X'080F6051'.
~~~~~~~~~~~~~~~~~~~~
The SNA Formats manual tells me that 080F6051 is:
~~~~~~~~~~~~~~~~~~~~
Access Security Information Invalid: The request specifies an Access
Security Information field that is unacceptable to the receiver; for
security reasons, no further detail on the error is provided. This sense
data is sent in FMH-7 or UNBIND.
~~~~~~~~~~~~~~~~~~~~
On the 515, I am getting this error:
~~~~~~~~~~~~~~~~~~~~
Message ID . . . . . . : CPF1269 Severity . . . . . . . : 00
Message type . . . . . : Information
Date sent . . . . . . : 10/19/07 Time sent . . . . . . :
09:29:07
Message . . . . : Program start request received on communications device
SYSTEM was rejected with reason codes 715, 0.
Cause . . . . . : The program start request was rejected in job
001111/QSYS/QCMN. The device belongs to remote location SYSTEM. If the
device is an advanced program-to-program communications (APPC) device,
the
program start request was received on mode QSOCCT with unit-of-work
identifier APPN.SYSTEM-C15E493CFBFB-0001. The first reason code means:
Neither password nor user ID was provided, and no default user profile
was
specified in the communications entry. The second reason code means:
None.
Recovery . . . : See the job log for more information about the problem.
~~~~~~~~~~~~~~~~~~~~
I am using QSECOFR with the same pwd on both servers, so I have no apparent
security issues. QRMTSIGN was tested with *SAMEPRF and *VERIFY for the same
result.
Any ideas?
--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list
To post a message email: MIDRANGE-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit:
http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at
http://archive.midrange.com/midrange-l.
As an Amazon Associate we earn from qualifying purchases.