DSPMSGD CPA3394 /* then, option 2=Field data shows: */
Message ID . . . . : CPA3394
Message file . . . : QCPFMSG
Library . . . . : QSYS
Message text . . . : Load form type '&4' device &5 writer &1.
Display Field Data
Field Data Type Length
&1 *CHAR 10
&2 *CHAR 10
&3 *CHAR 10
&4 *CHAR 10
&5 *CHAR 10
From the above, the device is &5, and that occupies positions 41 to
50. The second 'M' in the ten-byte name for &5 is in position 8, so the
first 40 characters [taken by &1 to &4] plus 8 more makes 48; i.e. the
request to make the comparison of 'M' to the expected position should be:
ADDRPYLE CMPDTA(M 48)
Regards, Chuck
--
All comments provided "as is" with no warranties of any kind
whatsoever and may not represent positions, strategies, nor views of my
employer
jmmckee@xxxxxxxxxxxxxx wrote:
I apparently am having a bad math day. In the message below, what position is
the second "M' in the device?
Load form type 'LG1' device MISP082M writer MISP082M. (G B I H R C)
John McKee
--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list
To post a message email: MIDRANGE-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/midrange-l.
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.