Hello Dwayne, I created a CL and RPG program to do this. The CL does a WRKSPLF(*ALL) to *PRINT then copies the spool file to a physical. The RPG reads the physical then does a DLTSPLF using QCMDEXEC. In the RPG you can define what criteria to select/ignore. This is now in our job scheduler and deletes anything over 30 days old with the exception of one queue. Granted I had to run it for single output queues when I first set it up and over a number of weekends, but now it checks all outq's overnight and only takes a few minutes to run. Not the most up to date way to do it I am sure, but it works. HTH Steve
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].