  • From: Chris Bipes <rpg@xxxxxxxxxxxxxxx>
  • Date: Fri, 7 Apr 2000 08:13:22 -0700

A better approach would be to bridge the two location via TCP/IP LAN to LAN.
You can then go direct E10 to F50 or E10 to 620.  You can also go remote PC
client to E10 & F50 & 620.  We have a 128K Frame relay connection to a
remote site and to Local AS400s here.  I can logon directly to all three
AS400s.  There is less communications overhead.  (The F50 has to do a lot of
work to receive the spool files and send them back.)  You will also be able
to share the Local printer Attached to the E10 with both systems directly.
No receive and forward needed by the F50.  How fast is the modem eliminator?
19200 or 64k?  If you are using a V.35 you can really crank up the BPS if
the modem eliminator supports a faster speed.

Christopher K. Bipes     mailto:ChrisB@Cross-Check.com
Sr. Programmer/Analyst   mailto:Chris_Bipes@Yahoo.com
CrossCheck, Inc.         http://www.cross-check.com
6119 State Farm Drive    Phone: 707 586-0551 x 1102
Rohnert Park CA  94928 Fax: 707 586-1884

If consistency is the hobgoblin of little minds, only geniuses work here.
Karen Herbelin - Readers Digest 3/2000


-----Original Message-----
From: Dawn L. Detz [mailto:ddetz@sgi.net]
Sent: Friday, April 07, 2000 6:34 AM
To: MIDRANGE-L@midrange.com
Subject: communications



Please convince my mgmt what the problem is.

I have remote users in NY residing on an E10 V3.2 passing through (appc 64K)
to an F50 V3.2 in PA, some using a program called ELKE on the F50.  These
same ELKE users (off the F50 from the E10) are passing through via Modem
Eliminator to the 620 V4.2 (which physically sits next to the f50) using
JDE.

Problem:  The NY users say ELKE responce time is fine but JDE responce time
stinks....  To draw it out for you:

E10(NY) -> F50(PA) -> 620(PA) then sending splf etc back
620 -> F50 -> E10

Why do you think?  My mgmt wants explaination.  I told them we are using an
F50 as a server and it is NOT intended for this use.  Maybe if they hear it
from 20 other opinions it will help my case.

+---
| This is the Midrange System Mailing List!
| To submit a new message, send your mail to MIDRANGE-L@midrange.com.
| To subscribe to this list send email to MIDRANGE-L-SUB@midrange.com.
| To unsubscribe from this list send email to MIDRANGE-L-UNSUB@midrange.com.
| Questions should be directed to the list owner/operator:
david@midrange.com
+---
+---
| This is the Midrange System Mailing List!
| To submit a new message, send your mail to MIDRANGE-L@midrange.com.
| To subscribe to this list send email to MIDRANGE-L-SUB@midrange.com.
| To unsubscribe from this list send email to MIDRANGE-L-UNSUB@midrange.com.
| Questions should be directed to the list owner/operator: david@midrange.com
+---

As an Amazon Associate we earn from qualifying purchases.

This thread ...


Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].

Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.