If high then *IN10 = '1'
If low then *IN10 = '1'
If equal then *IN20='1'
Could also be like this...
C A COMP B 101520
Jim
-----Original Message-----
From: RPG400-L [mailto:rpg400-l-bounces@xxxxxxxxxxxxxxxxxx] On Behalf Of Booth Martin
Sent: Saturday, May 16, 2020 8:43 PM
To: RPG programming on the IBM i (AS/400 and iSeries) <rpg400-l@xxxxxxxxxxxxxxxxxx>
Subject: RPG COMP HiLoEq
Looking at some old code, and it confuses me. The reference manual left me in doubt.
C A COMP B 101020
Is there a condition in which *in10 will be on? In other words, can it ever be that A COMP B is both Hi & Lo? Or is that an OR condition?
--
This is the RPG programming on IBM i (RPG400-L) mailing list To post a message email: RPG400-L@xxxxxxxxxxxxxxxxxx To subscribe, unsubscribe, or change list options,
visit:
https://lists.midrange.com/mailman/listinfo/rpg400-l
or email: RPG400-L-request@xxxxxxxxxxxxxxxxxx
Before posting, please take a moment to review the archives at
https://archive.midrange.com/rpg400-l.
Please contact support@xxxxxxxxxxxxxxxxxxxx for any subscription related questions.
Help support midrange.com by shopping at amazon.com with our affiliate link:
https://amazon.midrange.com
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2025 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact
[javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.