Thats the only way I do it.
                 Install Options for Program Temporary Fixes
                                                            System:   MDS
Type choices, press Enter.
  Device  . . . . . . . . .   OPTVRT01     Name, *SERVICE, *NONE
  Automatic IPL . . . . . .   N            Y=Yes
                                           N=No
  Prompt for media  . . . .   3            1=Single PTF volume set
                                           2=Multiple PTF volume sets
                                           3=Multiple volume sets and *SERVICE
  Restart type  . . . . . .   *SYS         *SYS, *FULL
  Other options . . . . . .   Y            Y=Yes
                                           N=No
                            Other Install Options
                                                            System:   MDS
Type choices, press Enter.
  Omit PTFs  . .   N            Y=Yes, N=No
  Apply type . .   1            1=Set all PTFs delayed
                                2=Apply immediate, set delayed PTFs
                                3=Apply only immediate PTFs
  PTF type . . .   1            1=All PTFs
                                2=HIPER PTFs and HIPER LIC fixes only
                                3=HIPER LIC fixes only
                                4=Refresh Licensed Internal Code
  Copy PTFs  . .   N            Y=Yes, N=No
On Mon, 2020-09-21 at 12:23 -0400, Rich Loeber wrote:
Does anyone have experience with installing a CUM PTF set and specifying
no automatic IPL?  I do PTFs infrequently and would like to leave my
system up while the PTFs are being installed and the do the IPL myself
when it is done and I find a good time.
The PTF instructions that I received indicate that Y should be used.
Rich Loeber - @richloeber
Kisco Information Systems
<
http://www.kisco.com>
http://www.kisco.com
[
https://www.medtronsoftware.com/img/MedtronMinilogo.bmp]  Kevin  Bucknum
                   Senior Programmer Analyst
                   MEDDATA / MEDTRON
                   120 Innwood Drive
                   Covington LA 70433
                   Local: 985-893-2550
                   Toll Free: 877-893-2550
                 
https://www.medtronsoftware.com
CONFIDENTIALITY NOTICE
This document and any accompanying this email transmission contain confidential information, belonging to the sender that is legally privileged.  This information is intended only for the use of the individual or entity named above.  The authorized recipient of this information is prohibited from disclosing this information to any other party and is required to destroy the information after its stated need has been fulfilled.  If you are not the intended recipient, or the employee of agent responsible to deliver it to the intended recipient, you are hereby notified that any disclosure, copying, distribution or action taken in reliance on the contents of these documents is STRICTLY PROHIBITED.  If you have received this email in error, please notify the sender immediately to arrange for return or destruction of these documents.
As an Amazon Associate we earn from qualifying purchases.