Philipp, The point about checking that QUSER has MAXSTG(*NOMAX) is a good one. A long time ago in a cornfield far far away, IBM used to ship AS/400 systems with MAXSTG(3176) for QUSER, and if these systems have been upgraded over the years this may not have been changed. There are also some V5R2 PTF's that may help - SI08923, SI08871 & MF30604. Also check this link for TCP/IP stack PTF's: http://www-1.ibm.com/support/docview.wss?uid=nas1d890cb0927aa56ad86256a3100633d95&rs=110 Also, a less drastic solution than an IPL or ENDTCP *IMMED and STRTCP if this problem occurs and nothing else seems to be helping: 1) ENDHOSTSVR ALL 2) DLTUSRSPC QUSRSYS/QYSMSVRE 3) STRHOSTSVR *ALL ...Neil Philipp Rusch <Philipp.Rusch@xxxxxxxxxxxx> Sent by: midrange-l-bounces@xxxxxxxxxxxx 2003/06/02 15:25 To Midrange Systems Technical Discussion <midrange-l@xxxxxxxxxxxx> cc Subject Re: CWBDB0058 I've had this type of error when the staff restored some libs after upgrade without excluding QGPL and QUSRSYS. Afterwards nearly all TCPIP "prestarted jobs" seemed to start and then stopped immediately after. I reinstalled option 12 of SS1 and TC1-licpgm, and it worked again, using CA Express V4R4, V4R5 and V5R2, no difference. If having problems with CAWIN connections, always check on QUSER profile, max storage should be *NOMAX, look if it is not *DISABLED and refresh the password. HTH, Philipp Rusch "Smith, Dave" schrieb: > HELP! > > > > I have a client and their iSeries access data transfer quit working today (it was working this morning but now its not.) The error I am getting is: CWBDB0058 Unable to start database server due to communications error. > > > > Their system was upgraded to V5R2 last week but they have done transfers since. I've gone through STRPJ on QZDAINIT now in library QSYS (says itÃââs already started). I've done a STRHOSTSVR *ALL and IÃââve run CWBPING which gives me a CWBCO1008 - Unable to connect to server application Data Access, Returned 8006. I also got the same thing on application Network Print. I ended the PJ and restarted it and even had the luxury of being able to IPL the system (No comments please) I get the same error on all PCÃââs that attempt an iseries access transfer. I canÃâât find any error messages via the green screen side. iSeries Navigator says the database server is running, IÃââm not seeing any other error messages and everything else seems to be working. > > > David Smith
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.