Edmund,
I was updating a program written back in 2007, and the developer did advance usage of subprocedures....
So, when referencing an indicator inside the subprocedure, it does NOT show up on the global outline view! No Wonder it did not show up in the Main Indicator usage! That is why all version of RDP 8/8.5 & RDi 9 didn't show it!
So, I guess Indicator usage is NOT shown if used inside of procedure. Even though the indicator is a global Variable...
Oh well, I guess that now sort of makes sense! Even though the compile listing does show every place where the indicators are used!
So, is it possible to show the indicator usage across subprocedures?
Scanning seems work best for me, although I do love the outline view, on the information it give us.
-Ken Killian-
-----Original Message-----
From: wdsci-l-bounces@xxxxxxxxxxxx [mailto:wdsci-l-bounces@xxxxxxxxxxxx] On Behalf Of Edmund Reinhardt
Sent: Thursday, August 15, 2013 2:13 PM
To: Rational Developer for IBM i / Websphere Development Studio Client for System i & iSeries
Cc: wdsci-l-bounces@xxxxxxxxxxxx
Subject: Re: [WDSCI-L] RDP 8.03 --> Outline for Indicators NOT WORKING
FYI, The latest patch does not have a relevant fix for this.
Best solution would be to provide RPG and DSPF DDS snippet to reproduce.
Others could confirm issue and open APAR. We are not planning to enhance
the static outline, so the fix will go into the live outline, in a future release.
Regards,
Edmund (E.H.) Reinhardt
COBOL IDE on AIX, DDS, WebFacing, System i Application Development, Rational Developer for Power
2D barcode Phone: 1-905-413-3125 | Phone: 1-905-854-6195 IBM
- encoded E-mail: edmund.reinhardt@xxxxxxxxxx
with AIX COBOL: 8200 Warden Ave
contact www.youtube.com/user/IBMRational#g/c/62DF24D5BCD43501 Markham, ON L6G 1C7
information "In every thing give thanks: for this is the will of Canada
God in Christ Jesus concerning you." - 1
Thessalonians 5:18
From: Ken Killian <kkillian@xxxxxxxxxxxx>
To: "Rational Developer for IBM i / Websphere Development Studio
Client for System i & iSeries" <wdsci-l@xxxxxxxxxxxx>,
Date: 15/08/2013 10:06 AM
Subject: Re: [WDSCI-L] RDP 8.03 --> Outline for Indicators NOT WORKING
Sent by: wdsci-l-bounces@xxxxxxxxxxxx
Thanks Edmund! I always appreciate your feedback, and the team's hard work on the Rational Developer Software!
Yup, this SQLRPGLE, and the Compile list does show the *XREF, and shows the selected *indicator in the cross reference at the bottom of the compile listing...
The Indicator happens to be *IN28, and the compile list shows this:
*IN28 N(1) 32000006 41000003 050500M
052500M
120300M 134000M
143200M
This happens to be an indicator on the DDS keyword SFLEND.
Even creating a brand new work-space, the outline view did not show where the *indicator is being used...
Oh well, I have gone back to the Search, instead of the outline view...
I have tried RDi 9.0, and it does NOT either load Indictor usage properly in the outline view. I am on the trial, and have not applied that latest patch. I only have 4-days left on the trial RDi 9.0 anyway...
It show "*IN28" in the Indicator view. But does not show the 7-lines where referenced. Instead, when I click on it, it only shows the first occurrence of the reference to *in28. <Puzzled-Look> Just like RDP 8.0 and 8.5
I try to encourage my fellow developers to use Rational Developer, so I have a stronger case to convince management to purchase the support and get the new version of RDi 9.0. But, with approx. 70% developers NOT using Rational. It is a hard sell... <frown> And any minor glitch that pops up on Rational, the newbies scream: "That is why I stick to SEU...". <sigh>
I for one, love using Rational over SEU! But, I have been using it 7-years actively, so I am use to little minor "quirks"...
<grin> It is still 100 times better than SEU!!! <Joy Joy>
-Ken Killian-
(423) 510-3129
-----Original Message-----
From: wdsci-l-bounces@xxxxxxxxxxxx [mailto:wdsci-l-bounces@xxxxxxxxxxxx] On Behalf Of Edmund Reinhardt
Sent: Thursday, August 15, 2013 9:30 AM
To: Rational Developer for IBM i / Websphere Development Studio Client for System i & iSeries
Subject: Re: [WDSCI-L] RDP 8.03 --> Outline for Indicators NOT WORKING
You might want to check the compiler listing XREF section, to see if it thinks those indicators are referenced. That is what the static outline in
8,0 is based on.
Regards,
Edmund (E.H.) Reinhardt
COBOL IDE on AIX, DDS, WebFacing, System i Application Development, Rational Developer for Power
2D barcode Phone: 1-905-413-3125 | Phone: 1-905-854-6195 IBM
- encoded E-mail: edmund.reinhardt@xxxxxxxxxx
with AIX COBOL:
8200 Warden Ave
contact www.youtube.com/user/IBMRational#g/c/62DF24D5BCD43501
Markham, ON L6G 1C7
information "In every thing give thanks: for this is the will of Canada
God in Christ Jesus concerning you." - 1
Thessalonians 5:18
From: Ken Killian <kkillian@xxxxxxxxxxxx>
To: "Rational Developer for IBM i / Websphere Development Studio
Client for System i & iSeries" <wdsci-l@xxxxxxxxxxxx>,
Date: 15/08/2013 08:03 AM
Subject: Re: [WDSCI-L] RDP 8.03 --> Outline for Indicators NOT
WORKING
Sent by: wdsci-l-bounces@xxxxxxxxxxxx
windows>preferences>Remote Systems>File Cache
Clicked the "Clear Cached Files" button, and the refreshed the outline view, and it still is not loading the indicator usage properly...
Recompiled the display file. Manually reload of the outline view. Then recompile the program, and manual refresh of the outline view. And the indictor usage is STILL NOT being loaded...
It does show in the indicator usage, just does not show the lines where it is used...
Am I missing some other place to manually reset?
This indictor is being referenced 5 places inside the code, and yet does not show it in the outline view. But, does use indicator usage for an indicator, that is only reference once...
This is perplexing...
-Ken Killian-
(423) 510-3129
-----Original Message-----
From: wdsci-l-bounces@xxxxxxxxxxxx [mailto:wdsci-l-bounces@xxxxxxxxxxxx] On Behalf Of Ken Killian
Sent: Thursday, August 15, 2013 7:52 AM
To: Rational Developer for IBM i / Websphere Development Studio Client for System i & iSeries
Subject: Re: [WDSCI-L] RDP 8.03 --> Outline for Indicators NOT WORKING
Note, I have changed the Workstn file, so, I am pretty sure this is related to the "Cache" not being "REFRESHED"
Is there a way to force a reload of the workstn for the outline view? I guess I will try to clear cache.
-Ken Killian-
(423) 510-3129
-----Original Message-----
From: wdsci-l-bounces@xxxxxxxxxxxx [mailto:wdsci-l-bounces@xxxxxxxxxxxx] On Behalf Of Ken Killian
Sent: Thursday, August 15, 2013 7:49 AM
To: Rational Developer for IBM i / Websphere Development Studio Client for System i & iSeries
Subject: [WDSCI-L] RDP 8.03 --> Outline for Indicators NOT WORKING
Hi,
It appears that outline view does not work. I am checking indicator usage on an existing program. And it does not show the lines where the indicator is being used. I did a manual refresh, and it still does not load...
Do I need to clear something to get the outline to work for indicators?
RDP 8.0
PS. My company has not purchased the license for 9.0, so I am now stuck on the previous release.
-Ken Killian-
--
This is the Rational Developer for IBM i / Websphere Development Studio Client for System i & iSeries (WDSCI-L) mailing list To post a message
email: WDSCI-L@xxxxxxxxxxxx To subscribe, unsubscribe, or change list options,
visit:
http://lists.midrange.com/mailman/listinfo/wdsci-l
or email: WDSCI-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives at
http://archive.midrange.com/wdsci-l.
--
This is the Rational Developer for IBM i / Websphere Development Studio Client for System i & iSeries (WDSCI-L) mailing list To post a message
email: WDSCI-L@xxxxxxxxxxxx To subscribe, unsubscribe, or change list options,
visit:
http://lists.midrange.com/mailman/listinfo/wdsci-l
or email: WDSCI-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives at
http://archive.midrange.com/wdsci-l.
--
This is the Rational Developer for IBM i / Websphere Development Studio Client for System i & iSeries (WDSCI-L) mailing list To post a message
email: WDSCI-L@xxxxxxxxxxxx To subscribe, unsubscribe, or change list options,
visit:
http://lists.midrange.com/mailman/listinfo/wdsci-l
or email: WDSCI-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives at
http://archive.midrange.com/wdsci-l.
--
This is the Rational Developer for IBM i / Websphere Development Studio Client for System i & iSeries (WDSCI-L) mailing list To post a message email: WDSCI-L@xxxxxxxxxxxx To subscribe, unsubscribe, or change list options,
visit:
http://lists.midrange.com/mailman/listinfo/wdsci-l
or email: WDSCI-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives at
http://archive.midrange.com/wdsci-l.
As an Amazon Associate we earn from qualifying purchases.