I was testing to see if Webfacing manages sessions (which it does--log on once and go back and forth between Webfaced apps), but I noticed that using the Webfaced apps left two interactive jobs running on the iSeries. The jobs were: QQF02D5680 KCOOKSON INTER ACTIVE QQF02D5681 KCOOKSON INTER ACTIVE PGM-QQFINVOKER I suspect the QQF02D5680 job had been running since yesterday, since my msgq was already allocated when I logged onto a session of Access for Windows this morning. These jobs continued to run on the iSeries even after I exited the Webfaced apps, closed my browser, and shut down the Web server. Is it expected? Is there anything I can do to end jobs when users end their sessions so we don't have interactive jobs running for no reason? Thanks, Kelly
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].