×
The internal search function is temporarily non-functional. The current search engine is no longer viable and we are researching alternatives.
As a stop gap measure, we are using Google's custom search engine service.
If you know of an easy to use, open source, search engine ... please contact support@midrange.com.
Make sure program is compiled with source ... then do strdbg and hit F10 ...
run program... should stop at line with problem...
-----Original Message-----
From: rpg400-l-bounces@xxxxxxxxxxxx [mailto:rpg400-l-bounces@xxxxxxxxxxxx]
On Behalf Of Charles Wilt
Sent: Wednesday, October 08, 2008 4:59 PM
To: RPG programming on the AS400 / iSeries
Subject: Permanent I/O Error occured to DSPF
All, I'm getting an error during I/O to a display file:
RNQ1251
Message . . . . : Permanent I/O error occurred in file FV011RP (C G D F).
Cause . . . . . : RPG procedure FV011R in program HLTHCURRLS/FV011R at
statement 11288 detected a permanent (not recoverable) file, session, or
device error. The session, device and/or program has been stopped. Examine
the major/minor return code value to determine the specific error that
occurred. If the major return code is 80 then a system or file error
occurred and programmer action is required to fix the problem. If the
major
return code is 81 then a session or device error occurred, but use of
Technical description . . . . . . . . : The major return code is 80. The
minor return code is C0.
CPF5192
Message . . . . : Data sent to device QPADEV001X not valid. Negative
response code is 10050129.
Cause . . . . . : The condition was caused by the program output data
containing below hex 40 or too many input fields. More information on the
negative response code can be found in either the IBM 5494 Remote Control
Unit Functions Reference (under negative responses) or the SNA Formats
Manual (under SENSE or LUSTAT codes). Invalid data (below hex 40) may
have
occurred in one of the following ways:
Invalid parameter data passed in variable to command language program.
Variable is used in SNDPGMMSG command. Command fails when data is
displayed.
Hexadecimal characters below hex 40 entered into TEXT parameter of
create
command. Display command for object fails when object parameters are
displayed.
Data base record containing invalid data displayed by the application
program.
Failure to specify RSTDSP(*YES) when alternating displays from more than
one file to the device, where both files have input fields.
I've looked at the dump, I don't see any invalid characters (< x'40').
I looked up the sense code and it says:
10050129 = Format table overflow
Does anybody have an idea of what's wrong?
Thanks!
Charles Wilt
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact
[javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.