Hmm.... Unless it is a service program, how can you exec a subprocedures without going thru main procedure. My understanding is that module is not execable. You use it to create a callable program or service program. If it is a callable program, it will have to go thru the main procedure to fire up the program. When the program is done, set on LR and return should close the file. Shouldn't it? Note: The company I work for do not allow create program using module. ==> Not familiar enough to be certain. -----Original Message----- From: rpg400-l-bounces@xxxxxxxxxxxx [mailto:rpg400-l-bounces@xxxxxxxxxxxx] On Behalf Of Scott Klement Sent: Friday, November 04, 2005 2:30 PM To: RPG programming on the AS400 / iSeries Subject: RE: ILE and Access Paths So if you're only calling subproceudres in the module, and never using the main procedure, and never executing the RPG cycle, *INLR will have no effect.
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2025 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].