Hi Rob,
Ok, what you're saying is that since SF98035 includes SF97710 that it includes a TR? Although when I search on the SF97710 link you gave, I don't find SF99707. And you're saying that the online documentation simply isn't up to date and it does include TR6?
I forwarded along Jim's email (thanks, Jim) to my manager.
Rob, you made a comment in a different thread about sadistic administrators. If only we had an administrator!
In regard to the cores, we don't run any LPARs. With a quick Google search I think I see what you're talking about in regard to assigning hardware resources to LPARs so they can run fairly independently.
-Kurt
-----Original Message-----
From: midrange-l-bounces@xxxxxxxxxxxx [mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of rob@xxxxxxxxx
Sent: Wednesday, May 15, 2013 10:03 AM
To: Midrange Systems Technical Discussion
Subject: Re: Cumulative PTF w/o Technology Refresh
Bad drugs. The current cume does include TR6
http://www-912.ibm.com/s_dir/sline003.nsf/2d3aff1c6b4d6ce086256453000d971e/d37adbbbf29e07eb8625770a005b18b3?OpenDocument
Search for the PTF's listed at
http://www-912.ibm.com/s_dir/sline003.NSF/554c38c4848b77f2862567bd0046e003/85fc5e8ebc0523048625779900742abc?OpenDocument
The latter document says that it's ptfs are not on a cume. It lies. It hasn't been updated since, well, Last Updated: 2/12/13 The cume's come out since then. If you notice any ptfs that are in the latter that are not on the cume let us know.
Rob Berendt
--
IBM Certified System Administrator - IBM i 6.1 Group Dekko Dept 1600 Mail to: 2505 Dekko Drive
Garrett, IN 46738
Ship to: Dock 108
6928N 400E
Kendallville, IN 46755
http://www.dekko.com
From: "Anderson, Kurt" <KAnderson@xxxxxxxxxxxx>
To: "'Midrange Systems Technical Discussion'"
<midrange-l@xxxxxxxxxxxx>,
Date: 05/15/2013 10:50 AM
Subject: Cumulative PTF w/o Technology Refresh
Sent by: midrange-l-bounces@xxxxxxxxxxxx
So we've been really bad about PTFs. Our IBM BP is asking that we apply
PTFs because after getting an additional core activated (from 1 to 2)
we've noticed 0 improvement on the system.
So we finally ordered a cumulative PTF and we're looking at applying it.
But then I thought, "What about technology refreshes?" It doesn't appear
that the cume comes with a TR on it. Cume: C3037710
http://www-912.ibm.com/systems/electronic/support/s_dir/sline003.nsf/PSP%20Number%20View/SF98035
Are we safe to apply the Cume w/o a TR and then later investigate applying
a Technology Refresh?
Thanks,
Kurt Anderson
Sr. Programmer/Analyst
CustomCall Data Systems, a division of Enghouse Systems Ltd