This is interesting.
I have:
MF56173 applied permanently.
MF99005 applied permanently.
SF99707 level 4 installed.
SF99707 level 5 apply at next IPL.
Single LPAR, 1 processor.
Wonder what's going to happen when I IPL . . .
:)
On Wed, Oct 31, 2012 at 1:38 PM, <rob@xxxxxxxxx> wrote:
In the cover letter for MF99005, available atwww-912.ibm.com/a_dir/as4ptf.nsf/86acab6961d02f8386257707005030d2/efadb01fd36ef39d86257a61004ce8d9?OpenDocument
It mentions nothing about MF561735
It does say this:
Special Instructions
Please ensure that you have a SAVSYS before applying this PTF.
Permanently apply any temporarily applied LIC PTFs on your partition
before applying this PTF.
This PTF must be permanently applied.
BUT, as it has been pointed out to me, MF99005 is not TR5; SF99707 level
is. And if you look at the cover letter for SF99707 you'll see thathttp://www-912.ibm.com/s_dir/sline003.nsf/PDFPbyNum/SF99707/$File/SF99707.pdf
MF56173 is included with SF99707.
So, you need MF56173 applied before you apply MF56173?will
Of course, MF56173 is a delayed PTF, designed to stop a hang during an
IPL. Of course, what's to stop the hang during the IPL applying MF56173?
Well, don't have any "previous failed system configuration change" is a
big start.
Probably it's a, "if you sneak by the hang on this IPL, then this PTF
prevent this type of hang on any future IPLs".list
Rob Berendt
--
IBM Certified System Administrator - IBM i 6.1
Group Dekko
Dept 1600
Mail to: 2505 Dekko Drive
Garrett, IN 46738
Ship to: Dock 108
6928N 400E
Kendallville, IN 46755
http://www.dekko.com
From: Gregory Martin <mr.gamartin@xxxxxxxxx>
To: Midrange Systems Technical Discussion <midrange-l@xxxxxxxxxxxx>,
Date: 10/31/2012 12:42 PM
Subject: Re: Applying TR5
Sent by: midrange-l-bounces@xxxxxxxxxxxx
We had an issue in installing TR5 as it hung during the IPL to apply the
PTF's. We call IBM and found out that we needed MF56173 to be applied
following the special instructions. Make sure you review MF56173
information before applying TR5.
--
Thanks,
Greg Martin
mailto:mr.gamartin@xxxxxxxxx
--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing
list
To post a message email: MIDRANGE-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/midrange-l.
--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing
To post a message email: MIDRANGE-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/midrange-l.
--
Jeff Crosby
VP Information Systems
UniPro FoodService/Dilgard
P.O. Box 13369
Ft. Wayne, IN 46868-3369
260-422-7531
www.dilgardfoods.com
The opinions expressed are my own and not necessarily the opinion of my
company. Unless I say so.
--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list
To post a message email: MIDRANGE-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/midrange-l.
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.