Everything works with HMC, only some systems work with SDMC. The very
newest "C" models of POWER7 do not work with SDMC.
With 'dumb moves' like that you'd think IBM didn't care about the SDMC.
Personally I'm staying with HMC. ;-) ;-)
- Larry "DrFranken" Bolhuis
On 4/9/2012 11:48 AM, William.Epperson@xxxxxxxxxxxxxxxxxxxxxxxx wrote:
Good to know, I hadn't heard that before. Do you have the chart thatshows
which Power7's are incompatible with the SDMC? Would appreciate thatand
information as we begin migrating off of our CR2 HMC and these two other
CR3's. We still have too many older systems to completely get rid of our
HMC's at the moment, but we're getting there, gradually.
Thank you,
William G. Epperson Jr.
Systems Communications Analyst II
2420 East Pikes Peak
Colorado Springs, CO 80909
Office: 719-365-8831
Mission: To provide the highest quality health care
Vision: To create an outstanding health system where patients heal
people thriveis
Values: Compassion - Integrity - Quality - Respect - Teamwork
www.memorialhealthsystem.com
The information contained in or attached to this electronic message
privileged and confidential, intended only for the use of theindividual
(s) named above. If the reader of this message is not the intendedprohibited.
recipient, or the employee or agent responsible to deliver it to the
intended recipient, you are hereby notified that any dissemination,
distribution, or copying of this communication is strictly
If you have received this communication in error, please inform theand
sender immediately and remove any record of this message.
From: rob@xxxxxxxxx
To: Midrange Systems Technical Discussion<midrange-l@xxxxxxxxxxxx>
Date: 04/06/2012 10:14 AM
Subject: Re: Configuring Brand New ISeries ASMI / HMC
Sent by: midrange-l-bounces@xxxxxxxxxxxx
Some of the largest power 7's won't work with sdmc according to a chart I
was looking at earlier.
Rob Berendt
--
Group Dekko
Dept 1600
Mail to: 2505 Dekko Drive
Garrett, IN 46738
Ship to: Dock 108
6928N 400E
Kendallville, IN 46755
http://www.dekko.com
From: William.Epperson@xxxxxxxxxxxxxxxxxxxxxxxx
To: Midrange Systems Technical Discussion<midrange-l@xxxxxxxxxxxx>,
Cc: midrange-l-bounces@xxxxxxxxxxxx
Date: 04/06/2012 12:07 PM
Subject: Re: Configuring Brand New ISeries ASMI / HMC
Sent by: midrange-l-bounces@xxxxxxxxxxxx
You may look at just running an SDMC console and setting that up. I have
heard that there are some things that the SDMC still will not do that a
physical HMC will do. I know that IBM is trying to get off of the HMC
they're pushing either the SDMC or Systems Director. I also know you cansimple,
run an SDMC as a virtual server but it must include a "second" ethernet
device for connecting into the HMC side of the Power7 systems in order to
manage them. I'm researching this for our installations to see if it
makes
sense to drop a virtual machine on my Linux virtual cluster rather than
trying to run it in our VMware environment. It'll just be a matter of
piping another vlan into my linux cluster. If you want to make it
just run a small Linux workstation and install it with two ethernethttps://www.ibm.com/developerworks/mydeveloperworks/blogs/aixpert/entry/systems_director_management_console_sdmc_redbook_get_yours_now2?lang=en
devices. It doesn't need much resources to run, but there must be a DHCP
server on that private network to generate the IP's for the Power7
systems.
and
Thank you,
William G. Epperson Jr.
Systems Communications Analyst II
2420 East Pikes Peak
Colorado Springs, CO 80909
Office: 719-365-8831
Mission: To provide the highest quality health care
Vision: To create an outstanding health system where patients heal
is
people thrive
Values: Compassion - Integrity - Quality - Respect - Teamwork
www.memorialhealthsystem.com
The information contained in or attached to this electronic message
prohibited.
privileged and confidential, intended only for the use of the
individual
(s) named above. If the reader of this message is not the intended
recipient, or the employee or agent responsible to deliver it to the
intended recipient, you are hereby notified that any dissemination,
distribution, or copying of this communication is strictly
he
If you have received this communication in error, please inform the
sender immediately and remove any record of this message.
From: rob@xxxxxxxxx
To: Midrange Systems Technical Discussion
<midrange-l@xxxxxxxxxxxx>
Date: 04/06/2012 05:23 AM
Subject: Re: Configuring Brand New ISeries ASMI / HMC
Sent by: midrange-l-bounces@xxxxxxxxxxxx
Kirk,
How do I reconcile what you've said:
No More HEA's on the E4C models.
With what James said:
We have: HMC1, HMC2, S1, S2, T1-T4.
Isn't T1-T4 indicative of HEA? Or is there some sort of other 4 port
ethernet card?
And, as another poster said, I was a little confused also as to whether
wanted HMC or Lan Console.http://www.ibm.com/developerworks/wikis/download/attachments/53871900/HMC
- We can access ASMI, but can't seem to run an HMC device.
- ...but still can't seem to get the Operations Console going...
So my first answer leaned towards Lan Console.
But let me duck back to HMC. I wonder what sort of HMC. Our HMC's are
too old for Power 7 equipment.
Let's see, 720
+and+Firmware+AIX+VUG_Feb+2011.pdf?version=1http://www-933.ibm.com/support/fixcentral/firmware/readme?fixid=MH01273#enhance7740
POWER7 requires HMC firmware level V7.710 or later
and
HMC
If an HMC is used to manage any POWER7 processor based server, the
must be a model CR3 or later model rack-mount HMC or C05 or laterdeskside
HMC.each
We have CR2's.
Rob Berendt
--
Group Dekko
Dept 1600
Mail to: 2505 Dekko Drive
Garrett, IN 46738
Ship to: Dock 108
6928N 400E
Kendallville, IN 46755
http://www.dekko.com
From: Kirk Goins<kirkgoins@xxxxxxxxx>
To: Midrange Systems Technical Discussion<midrange-l@xxxxxxxxxxxx>,
Date: 04/05/2012 04:53 PM
Subject: Re: Configuring Brand New ISeries ASMI / HMC
Sent by: midrange-l-bounces@xxxxxxxxxxxx
No More HEA's on the E4C models. They are using a 5767 Dual Port GB NIC
instead. It can NOT be split or Virtualized across partitions. So if you
want real External Ports for each partition, you will need cards for
partirtionThe Top Port will be where the system looks for the LANCONSOLE.
The card I believe by default will be in Slot C6.list
On Thu, Apr 5, 2012 at 12:57 PM,<rob@xxxxxxxxx> wrote:
There are better minds than me on this list when it comes to that. ButAnd
I'll give it a shot. HEA is Host Ethernet Adapter. T1-T4 are those.
since it's brand new and I suspect cost more than a can of pop out ofthe
soda machine I'd call IBM on a whim if you're still stuck. Mostcustomers
don't belittle you for calling IBM and grabbing that life line. They'dpoint
rather belittle you for taking days to get done the 'simple' stuff.
Rob Berendt
--
Group Dekko
Dept 1600
Mail to: 2505 Dekko Drive
Garrett, IN 46738
Ship to: Dock 108
6928N 400E
Kendallville, IN 46755
http://www.dekko.com
From: James LeLeux<james.leleux@xxxxxxxxx>
To: Midrange Systems Technical Discussion<midrange-l@xxxxxxxxxxxx>,
Date: 04/05/2012 03:51 PM
Subject: Configuring Brand New ISeries ASMI / HMC
Sent by: midrange-l-bounces@xxxxxxxxxxxx
Hello,
Just got a 720 Power ISeries in yesterday and am having a heck of a time
getting it configured for Operations Console. The box I was using last
couple of weeks is a few years old, so it was a bit different and went
ever
so smoothly.
We can access ASMI, but can't seem to run an HMC device. Have a Neoware
appliance that I've used for my other box, but can seem to get it to see
the new box.
We have the HMC IP's.
I think there is a basic step we are missing. Reading manuals and such,
but
still can't seem to get the Operations Console going.
The manual states to use the 'first port' HEA or C1, but no such label
exists on the box.
We have: HMC1, HMC2, S1, S2, T1-T4.
Not sure I even formulated an intellgent question, but if anyone can
me in the right direction I'd appreciate it.list
Thanks!!
--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing
list
To post a message email: MIDRANGE-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/midrange-l.
--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing
To post a message email: MIDRANGE-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/midrange-l.
--
Kirk
--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing
list
To post a message email: MIDRANGE-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/midrange-l.
--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing
list
To post a message email: MIDRANGE-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/midrange-l.
--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing
list
To post a message email: MIDRANGE-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/midrange-l.
--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing
To post a message email: MIDRANGE-L@xxxxxxxxxxxx--
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/midrange-l.
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list
To post a message email: MIDRANGE-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/midrange-l.
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2025 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.