× The internal search function is temporarily non-functional. The current search engine is no longer viable and we are researching alternatives.
As a stop gap measure, we are using Google's custom search engine service.
If you know of an easy to use, open source, search engine ... please contact support@midrange.com.



Quoting Lukas Beeler <lukas.beeler@xxxxxxxxxxxxxxxx>:

On Mon, Oct 12, 2009 at 18:22, Roger Vicker, CCP <rv-tech@xxxxxxxxxx> wrote:
I had them hit the power button and it seemed to be starting but it has
been sitting at SRC C600 3915 for over an hour. The description is
"Licensed internal code (LIC) has initiated the load source IOP
self-load." so I am thinking this should be a quick step instead. The
customer is not reporting an alert light yet. I hope to get onsite in an
hour.

I've seen a machine stuck on this message before. It was a 250 oder
270. It was a broken disk - resolution was to pull the load source and
have the system IPL from the mirror. Worked fine after replacing the
disk.

Might be something else in your case, though.

Does this still sound like an Oh Frack or the rare Like A PC and reboot
it again?

I'd try to IPL again first. The disk controllers on the Power 520
models are rather flaky, and i've seen at least two machines that
sometimes just wouldn't IPL. A powercycle would help them get back on
track.


Onsite now.

I forgot to mention that this was a 9406-800 model.

I think this is the first time I have ever treated the IBM i like a PC. Pulling the power cords and waiting 10 seconds after the lights in the power supplies went completely out before rebooting seems to be working. It went by C6003915 in under 5 minutes and and came fully alive in 10.

Thanks.

Roger


As an Amazon Associate we earn from qualifying purchases.

This thread ...

Follow-Ups:
Replies:

Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].

Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.