Wow! Ok, trivia king - what's the type for? I was looking for it the other day, and I swore I've seen it before (like for example, 6707-070-x - what's x mean?) but I can't find it. Model - Level - Type, I believe it what disks are represented as. Below are levels, IIRC. -- Justin C. Haase - Solution Engineer IBM Certified Systems Expert - System i Kingland Systems Corporation -----Original Message----- From: midrange-l-bounces@xxxxxxxxxxxx [mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Leif Guldbrand - Think400.dk Sent: Wednesday, January 03, 2007 3:00 PM To: Midrange Systems Technical Discussion Subject: Re: Removing a failed drive permanently And for the archieves - Disk models (may not be up to date): 030 - Unprotected or mirrored unit of a type not supported in HA controller parity set (520-byte device). 050 - Unprotected or mirrored unit of a type supported in HA controller parity set membership (522-byte device). Data compression inactive 060 - Unprotected or mirrored unit of a type supported in HA controller parity set membership (522-byte device). Data compression active 070 - Non-parity unit of parity set (full capacity, 522-byte device). Data compression inactive 072 - Parity unit in parity set with 8 parity units (7/8 capacity, 522-byte device). Data compression inactive 074 - Parity unit in parity set with 4 parity units (3/4 capacity, 522-byte device). Data compression inactive. 080 - Non-parity unit of parity set (full capacity, 522-byte device). Data compression active 082 - Parity unit in parity set with 8 parity units (7/8 capacity, 522-byte device). Data compression active 084 - Parity unit in parity set with 4 parity units (3/4 capacity, 522-byte device). Data compression active Regards Leif ----- Original Message ----- From: "Larry Bolhuis" <lbolhuis@xxxxxxxxxx> To: "Midrange Systems Technical Discussion" <midrange-l@xxxxxxxxxxxx> Sent: 3. januar 2007 21:27 Subject: Re: Removing a failed drive permanently
If the drive is a model 070 then you can remove it from the ASP and
then
from the RAID set and then from the system. If it's any other 07x
number
then you need to remove it from the ASP, then end RAID, then remove
it,
then restart RAID. - Larry Pete Helgren wrote:I have replaced a failed drive with a new drive before but I'd like
to
pull one that I have no intention of replacing. The system is at
only
20% and losing a 8GB drive will make virtually no difference in
overall
capacity (this is a seldom used test/development system). Once I pull the failed drive, what do I run so that the RAID set
"knows"
that the drive won't replaced and that it has to rebuild the "lost" drive using the remaining drives in the set? Thanks, Pete Helgren
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.