× The internal search function is temporarily non-functional. The current search engine is no longer viable and we are researching alternatives.
As a stop gap measure, we are using Google's custom search engine service.
If you know of an easy to use, open source, search engine ... please contact support@midrange.com.



If the drive is a model 070 then you can remove it from the ASP and then from the RAID set and then from the system. If it's any other 07x number then you need to remove it from the ASP, then end RAID, then remove it, then restart RAID.

 - Larry

Pete Helgren wrote:
I have replaced a failed drive with a new drive before but I'd like to pull one that I have no intention of replacing. The system is at only 20% and losing a 8GB drive will make virtually no difference in overall capacity (this is a seldom used test/development system).

Once I pull the failed drive, what do I run so that the RAID set "knows" that the drive won't replaced and that it has to rebuild the "lost" drive using the remaining drives in the set?

Thanks,

Pete Helgren


As an Amazon Associate we earn from qualifying purchases.

This thread ...

Follow-Ups:
Replies:

Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].

Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.