|
I've now done 2 upgrades to V5R3 using C5298 with build dates on them of 12/03/05 or later and had no problems. I did a Go PTF #8 and loaded the CUME and HYPER/DB Group cds. After the last CD it informed me that I needed IPL and to apply 1 or more pre-req PTFs and to return to Go PTF #8 after the IPL. After the IPL I did go back to # and a message came up informing me I had more PTFs to apply and gave me the option to re-ipl and finish install the PTFs which I did and all is well. I then applied the rest of my Group PTfs etc. Looks like that have the install fixed... _____________________ Kirk Goins CCNA Systems Engineer, Manage Inc. IBM Certified i5 Solution Sales IBM Certified iSeries Solutions Expert IBM Certified Designing IBM e-business Solutions Office 503-353-1721 x106 Cell 503-577-9519 kirkg@xxxxxxxxxxxxx www.manageinc.com There are 10 types of people in the world: Those that understand binary, and those that don't. "Harvell, Joel" <jbharvell@xxxxxxxxxxxx> Sent by: midrange-l-bounces@xxxxxxxxxxxx 12/09/2005 06:20 AM Please respond to Midrange Systems Technical Discussion <midrange-l@xxxxxxxxxxxx> To "Midrange Systems Technical Discussion" <midrange-l@xxxxxxxxxxxx> cc Subject RE: CUME 5298 - Update I just installed CUME 5207 on all of our AS/400s. Before I started I read through SF98530 and noted that MF36693 & MF36564 had instructions to apply them before any Group or CUME. PTF MF35461 is listed on the CUME Install instructions as needing to be installed before the CUME too. Merry Christmas Joel B. Harvell Food Lion, LLC (704) 633-8250 x2709 -----Original Message----- From: midrange-l-bounces@xxxxxxxxxxxx [mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Ingvaldson, Scott Sent: Friday, December 09, 2005 8:53 AM To: midrange-l@xxxxxxxxxxxx Subject: RE: CUME 5298 - Update That is my thought also. I was surprised that these messages (in my case) were associated with the DB and Hiper PTFs though. This would indicate that everyone would need to install SI17595, MF36564, & MF36693 before attempting any other PTF install, not just the Cume. The question would be, do we NEED all of them installed before applying any further PTFs? ----------------------------------------------------------------- APAR for SI17595: The PTF apply process during IPL fails with CPF3662 when a required PTF is not in the correct state. For example, a 5722SS1 PTF was not applied because a 5722999 requisite PTF was not permanently applied. APAR for MF36564: The symptom is that the system crashes while trying to signon to XPF. APAR for MF36693: There are various instances during the apply of licensed internal code PTFs where the linkloader allows modules to crossover into alternate spaces. ----------------------------------------------------------------- In our production environment this makes the C5298530 (or Hiper #66) install a two month process. It would be nice if the instructions made more obvious which PTF or PTFs require these prereqs, so that we could install the rest immediately. Regards, Scott Ingvaldson iSeries System Administrator GuideOne Insurance Group -----Original Message----- date: Fri, 9 Dec 2005 00:42:48 -0500 (EST) from: "Pete Massiello" <pmassiello@xxxxxxxxxxxxxxxx> subject: Re: CUME 5298 - Update Scott, If you had IPLed after installing SI17595, MF36564, & MF36693 before loading the new Cume, I think you would have found the process would have loaded and applied like a normal cume. Pete ---------------------------- Original Message ---------------------------- Subject: CUME 5298 - Update From: "Ingvaldson, Scott" <SIngvaldson@xxxxxxxxxxxx> Date: Thu, December 8, 2005 12:38 pm To: midrange-l@xxxxxxxxxxxx ------------------------------------------------------------------------ -- > I ordered C5298530 on 12/01 and it arrived yesterday. I had already > downloaded SI17595, MF36564 and MF36693. SI17595 was temp applied and > the MF's were set to apply on IPL. Since this is the test system I > decided to try to install the Hipers (66) and DB (7) groups at this time > as well. > > Near the end of the Hiper and DB PTF load I received this message: > > ================================================================= > Confirm IPL for Special Handling PTFs > > There is at least one special handling PTF that requires an IPL to be > applied. A special handling PTF exists for a PTF group indicating the > PTF must be applied before the remaining PTFs in the PTF group are > applied. After the IPL, enter GO PTF and select option 8 again to apply > > the remaining PTFs. > > Press F10 to confirm your choice to end all jobs on the system > immediately and automatically IPL the system. > Press F12 to cancel the installation. > ================================================================= > I pressed F12 and did a normal IPL. After the IPL MF36564 and MF36693 > were temp applied, but none of the other PTFs were applied. > > WRKPTFGRP shows: > PTF Group Level Status > SF99530 5298 Not installed (was 5207) > SF99529 66 Not installed (was level 60) > SF99503 7 Installed (was level 6) > > When I did GO PTF option 8 now I got this message: > > ================================================================= > Continue PTF Install > > > The previous PTF install was incomplete. All PTFs were loaded from the > specified device, but the PTFs were not applied. There was at least one > special handling PTF that required a normal mode IPL to be applied. A > special handling PTF exists for a PTF group indicating the PTF must be > applied before the remaining PTFs in the PTF group are applied. > > > Do one of the following to continue the install: > o Press Enter to continue the previous PTF install without loading > additional PTFs from an install device. > o Press F6 to load additional PTFs from the install device, and then > apply all loaded PTFs. > > > Press F12 to cancel the installation. > ================================================================Enter set > all of these PTFs to apply, I then loaded C5298530 and IPLed. > > After IPLing all groups show applied. > > > Regards, > > Scott Ingvaldson > iSeries System Administrator > GuideOne Insurance Group DISCLAIMER: This message and accompanying documents are covered by the Electronic Communications Privacy Act, 18 U.S.C. ?? 2510-2521, and contains information intended for the specified individual(s) only. This information is confidential. If you are not the intended recipient or an agent responsible for delivering it to the intended recipient, you are hereby notified that you have received this document in error and that any review, dissemination, copying, or the taking of any action based on the contents of this information is strictly prohibited. If you have received this communication in error, please notify us immediately by e-mail, and delete the original message.
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.