Andy answered, comments inline. > No, you don't need to make the machine pool bigger because > you've added additional memory. I Disagree. The table of all memory pages is in the machine pool. So it needs to be increased. > Best bet would be to examine the faulting rates in your various > pools, including the machine pool. True, but difficult, as the guidelines has disappeared (see below). > The work management manual will provide guidelines > for acceptable levels depending on the power of the machine. Not any more. > If you have oodles of memory now, why not just turn on the automatic > adjustment and see where the pools settle. The auto tuning works much > better than it did in the older releases and might just make your life > easier and your users happier. I totally agree with that. Best regards Richard THEIS AS/400 Education, France theis_richard@fr.ibm.com
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2025 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].