Chuck, We had an almost identical problem about a month ago. We are on V4R4 but the rest of the network is the same. We tried all morning to vary things on/off, look for info on the message that we were getting, and were nowhere by the afternoon. We called the people that put in the remote controller and they had a tech go onsite. He found the boot diskette for the Perle to be bad. He recreated the diskette, re-booted the Perle and everything came back up. We didn't have any sessions up like one of your sites. It sounds weird but it worked for us. HTH. Ed Chabot The Marlin Firearms Company 100 Kenna Drive North Haven, CT 06473 (203)985-3254 -----Original Message----- From: midrange-l-admin@midrange.com [mailto:midrange-l-admin@midrange.com]On Behalf Of Chuck Lewis Sent: Monday, November 05, 2001 8:21 AM To: Midrange-L List Subject: Problems with remote devices... Hi Folks, FINALLY went from V4R1 to V4R5 this weekend and it went very well and pretty fast ! After we came up it appeared everything was OK. NOW I see that we have some devices at remote locations (network is Frame Relay, TCP/IP, Ethernet, Perle Control Units, Cisco Routers) that are not working. An example of the error message I am getting: Session start request failed for device MA03 on controller MA010RMT00. (CPF9366) Message ID . . . . . . : CPF9366 Severity . . . . . . . : 40 Message type . . . . . : Diagnostic Date sent . . . . . . : 11/05/01 Time sent . . . . . . : 07:54:39 Message . . . . : Session start request failed for device MA03 on controller MA010RMT00. Cause . . . . . : The request to start a session for a device MA03 on controller MA010RMT00 using mode QRMTWSC on APPC device MA0102 failed. This is a possible configuration problem. Recovery . . . : The Mode QRMTWSC might be incorrect. Compare the active number of sessions with the configured session limit of mode QRMTWSC (DSPMODSTS command). If they are equal, increase the maximum sessions (MAXSSN) parameter of the mode description (CHGMODD command). Make sure the maximum sessions (MAXSSN) and maximum conversations (MAXCNV) parameters are at least one greater than the number of devices attached to controller MA010RMT00. The locally controlled sessions (LCLCTLSSN) should be equal to or greater than the number of devices attached to controller MA010RMT00. There might be a problem in the APPN network. Correct the problem and the system will retry activation. Technical description . . . . . . . . : The request to start a new session failed with Systems Network Architecture (SNA) sense code X'00000000'. A sense code of 00000000 indicates that there is no sense code for this error Descriptions of SNA sense codes are available in the IBM SNA Formats, GA27-3136 and in the APPN Support book, SC41-5407. Check the QSYSOPR message queue for message CPP1236. This message can provide additional information about the failure. I have NO idea why this would happen or what V4R5 would have changed - anyone ? This includes one site completely down but I can ping the router AND control unit with NO PROBLEMS... And another site that has the MAJORITY of devices working except for about 4 or 5. All devices in both situations had LEFT hand cursor too !! And at the site with most devices working, deleting one of the failed decives and waiting a couple of minutes - the system recreates the device and I get the SAME message for this newly created device ! Really weird ! Thanks ! Chuck _______________________________________________ This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list To post a message email: MIDRANGE-L@midrange.com To subscribe, unsubscribe, or change list options, visit: http://lists.midrange.com/cgi-bin/listinfo/midrange-l or email: MIDRANGE-L-request@midrange.com Before posting, please take a moment to review the archives at http://archive.midrange.com/midrange-l.
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.