M Hello Dan, You wrote: >If the system initiates power off because the UPS supplied-power has >been on longer than that specified in the QUPSDLYTIM system value, what >kind of power down is it? I.e. >PWRDWNSYS *IMMED >PWRDWNSYS *CNTRLD DELAY(3600) <İİ this is the system default >PWRDWNSYS *CNTRLD DELAY(????) D) None of the above. It simply saves main storage or using CPM keeps main storage state and kills the box. If it successfully saved main storage then LIC will consider the next IPL normal however OS/400 never considers the IPL normal. To perform a clean shutdown you must install or write a UPS monitoring program. >Is this documented anywhere? I have not been able to find answers to >this specific question. It used to be documented in the Backup and Recovery Guide but they moved it to the Information Centre. Regards, Simon Coulter. «»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«» «» FlyByNight Software AS/400 Technical Specialists «» «» Eclipse the competition - run your business on an IBM AS/400. «» «» «» «» Phone: +61 3 9419 0175 Mobile: +61 0411 091 400 /"\ «» «» Fax: +61 3 9419 0175 mailto: shc@flybynight.com.au \ / «» «» X «» «» ASCII Ribbon campaign against HTML E-Mail / \ «» «»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.