We have a software vendor who provides support via ECS. We must enter a
command for our AS/400 to dial their AS/400. Unfortunately, it's a long
distance call and sometimes the vendor is inactive (session is in DSPW) for
long periods of time without disconnecting. It's bad enough we have to pay
for the call when they are actually working on it but it's worse when
they're not. We would like to take control rather than having to rely on
the vendor.
Is it possible to setup something on our AS/400 to automatically disconnect
the line once a specified inactivity time limit is reached? Any
information would be greatly appreciated. Thanks.
Below are the configurations:
Display Line Description Page
1
5769SS1 V4R3M0 980729 AS400 09/15/00
11:04:41
Line description . . . . . . . . . : LIND VNDLINE
Option . . . . . . . . . . . . . . : OPTION *ALL
Category of line . . . . . . . . . : *SDLC
Resource names . . . . . . . . . . : RSRCNAME CMN03
Online at IPL . . . . . . . . . . : ONLINE *NO
Data link role . . . . . . . . . . : ROLE *SEC
Physical interface . . . . . . . . : INTERFACE *RS232V24
Connection type . . . . . . . . . : CNN *SWTPP
Vary on wait . . . . . . . . . . . : VRYWAIT *NOWAIT
Autocall unit . . . . . . . . . . : AUTOCALL *NO
Exchange identifier . . . . . . . : EXCHID 05643159
NRZI data encoding . . . . . . . . : NRZI *YES
Maximum controllers . . . . . . . : MAXCTL 1
Clocking . . . . . . . . . . . . . : CLOCK *MODEM
Line speed . . . . . . . . . . . . : LINESPEED 19200
Modem type supported . . . . . . . : MODEM *V54
Modem data rate select . . . . . . : MODEMRATE *FULL
Switched connection type . . . . . : SWTCNN *BOTH
Autoanswer . . . . . . . . . . . . : AUTOANS *YES
Autoanswer type . . . . . . . . . : AUTOANSTYP *DTR
Autodial . . . . . . . . . . . . . : AUTODIAL *YES
Dial command type . . . . . . . . : DIALCMD *V25BIS
Calling number . . . . . . . . . . : CALLNBR *NONE
Station address . . . . . . . . . : STNADR 1C
Maximum frame size . . . . . . . . : MAXFRAME 521
Error threshold level . . . . . . : THRESHOLD *OFF
Duplex . . . . . . . . . . . . . . : DUPLEX *HALF
Modulus . . . . . . . . . . . . . : MODULUS 8
Text . . . . . . . . . . . . . . . : TEXT Line description for
sup
port
--------------Active Switched Controllers--------------
VNDCTL
Link speed . . . . . . . . . . . . : LINKSPEED 9600
Cost/connect time . . . . . . . . : COSTCNN 128
Cost/byte . . . . . . . . . . . . : COSTBYTE 128
Security for line . . . . . . . . : SECURITY *NONSECURE
Propagation delay . . . . . . . . : PRPDLY *TELEPHONE
User-defined 1 . . . . . . . . . . : USRDFN1 128
User-defined 2 . . . . . . . . . . : USRDFN2 128
User-defined 3 . . . . . . . . . . : USRDFN3 128
Maximum outstanding frames . . . . : MAXOUT 7
Inactivity timer . . . . . . . . . : INACTTMR 300
Poll response delay . . . . . . . : POLLRSPDLY 0
Data Set Ready drop timer . . . . : DSRDRPTMR 6
Clear To Send timer . . . . . . . : CTSTMR 25
Remote answer timer . . . . . . . : RMTANSTMR 60
Recovery limits . . . . . . . . . : CMNRCYLMT
Count limit . . . . . . . . . . : 2
Time interval . . . . . . . . . : 5
Line description . . . . . . . . . : LIND VNDLINE
Option . . . . . . . . . . . . . . : OPTION *ALL
Category of line . . . . . . . . . : *SDLC
* * * * * E N D O F L I S T I N G * * * * *
Display Controller Description Page
1
5769SS1 V4R3M0 980729 AS400 09/15/00
11:05:01
Controller description . . . . . . : CTLD VNDCTL
Option . . . . . . . . . . . . . . : OPTION *ALL
Category of controller . . . . . . : *APPC
Link type . . . . . . . . . . . . : LINKTYPE *SDLC
Online at IPL . . . . . . . . . . : ONLINE *YES
Switched connection . . . . . . . : SWITCHED *YES
Short hold mode . . . . . . . . . : SHM *NO
Active switched line . . . . . . . : VNDLINE
Character code . . . . . . . . . . : CODE *EBCDIC
Maximum frame size . . . . . . . . : MAXFRAME 521
Current maximum frame size . . . . : 521
Remote network identifier . . . . : RMTNETID APPN
Remote control point . . . . . . . : RMTCPNAME VND
Initial connection . . . . . . . . : INLCNN *DIAL
Dial initiation . . . . . . . . . : DIALINIT *LINKTYPE
Connection number . . . . . . . . : CNNNBR SST1-407-304-4300
Switched disconnect . . . . . . . : SWTDSC *YES
Data link role . . . . . . . . . . : ROLE *NEG
Station address . . . . . . . . . : STNADR 1C
Autocreate device . . . . . . . . : AUTOCRTDEV *ALL
System job . . . . . . . . . . . . : QCMNARB02
Text . . . . . . . . . . . . . . . : TEXT Control unit for
support
Switched line list . . . . . . . . : SWTLINLST
--------------------Switched Lines---------------------
VNDLINE
Attached devices . . . . . . . . . : DEV
-------------------Attached Devices--------------------
VNDDEV
APPN-capable . . . . . . . . . . . : APPN *YES
APPN CP session support . . . . . : CPSSN *YES
APPN/HPR capable . . . . . . . . . : HPR *YES
HPR path switching . . . . . . . . : HPRPTHSWT *NO
APPN node type . . . . . . . . . . : NODETYPE *CALC
APPN transmission group number . . : TMSGRPNBR 1
APPN minimum switched status . . . : MINSWTSTS *VRYONPND
Autodelete device . . . . . . . . : AUTODLTDEV 1440
User-defined 1 . . . . . . . . . . : USRDFN1 *LIND
User-defined 2 . . . . . . . . . . : USRDFN2 *LIND
User-defined 3 . . . . . . . . . . : USRDFN3 *LIND
Predial delay . . . . . . . . . . : PREDIALDLY 6
Redial delay . . . . . . . . . . . : REDIALDLY 120
Dial retry . . . . . . . . . . . . : DIALRTY 2
Disconnect timer . . . . . . . . . : DSCTMR
Minimum connect timer . . . . . : 170
Disconnection delay timer . . . : 30
SDLC poll priority . . . . . . . . : POLLPTY *NO
SDLC poll limit . . . . . . . . . : POLLLMT 0
SDLC out limit . . . . . . . . . . : OUTLMT *POLLLMT
SDLC connect poll retry . . . . . : CNNPOLLRTY 7
Controller description . . . . . . : CTLD VNDCTL
Option . . . . . . . . . . . . . . : OPTION *ALL
Category of controller . . . . . . : *APPC
SDLC NDM poll timer . . . . . . . : NDMPOLLTMR *CALC
Recovery limits . . . . . . . . . : CMNRCYLMT
Count limit . . . . . . . . . . : 2
Time interval . . . . . . . . . : 5
* * * * * E N D O F L I S T I N G * * * * *
Display Device Description Page
1
5769SS1 V4R3M0 980729 AS400 09/15/00
11:05:16
Device description . . . . . . . . : DEVD VNDDEV
Option . . . . . . . . . . . . . . : OPTION *ALL
Category of device . . . . . . . . : *APPC
Automatically created . . . . . . : NO
Remote location . . . . . . . . . : RMTLOCNAME VND
Online at IPL . . . . . . . . . . : ONLINE *YES
Local location . . . . . . . . . . : LCLLOCNAME *NETATR
Remote network identifier . . . . : RMTNETID *NETATR
Attached controller . . . . . . . : CTL VNDCTL
Message queue . . . . . . . . . . : MSGQ QSYSOPR
Library . . . . . . . . . . . . : *LIBL
Local location address . . . . . . : LOCADR 00
APPN-capable . . . . . . . . . . . : APPN *YES
Single session . . . . . . . . . . : SNGSSN
Single session capable . . . . . : *NO
Text . . . . . . . . . . . . . . . : TEXT Device description for
s
upport
Mode . . . . . . . . . . . . . . . : MODE
-------------------------Mode--------------------------
*NETATR
-------------------Active modes--------------------
Job
Mode name User Number
SNASVCMG QLUS QSYS 861811
BLANK QCMN QSYS 861911
* * * * * E N D O F L I S T I N G * * * * *
Diana Hicks
Town of Jupiter
dianah@jupiter.fl.us
+---
| This is the Midrange System Mailing List!
| To submit a new message, send your mail to MIDRANGE-L@midrange.com.
| To subscribe to this list send email to MIDRANGE-L-SUB@midrange.com.
| To unsubscribe from this list send email to MIDRANGE-L-UNSUB@midrange.com.
| Questions should be directed to the list owner/operator: david@midrange.com
+---
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2025 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.