Art, The *VERIFY means you need to send a password and profile using the TN5250E before you can bypass signon. The password sent may be either clear-text or encrypted - that part is up to the Client. We have not seen any clients giving the user a switch to select clear/encrypted, but if they supported encrypted, I don't know why they would bother to do clear-text anymore. All that is encrypted is the password, data is not encrypted. For that, you need VPN or SSL. > Date: Wed, 14 Apr 1999 16:11:52 -0400 > From: "Art Tostaine, Jr." <art@link400.com> > Subject: RE: AS/400 internet conection > > How is the signon encrypted with the *VERIFY Option? > > Art Tostaine, Jr. > CCA, Inc. > Parlin, NJ 08859 -- J.S. (Jeffrey) Stevens AS/400 TCP/IP (Telnet/WSG/LPD) +--- | This is the Midrange System Mailing List! | To submit a new message, send your mail to MIDRANGE-L@midrange.com. | To subscribe to this list send email to MIDRANGE-L-SUB@midrange.com. | To unsubscribe from this list send email to MIDRANGE-L-UNSUB@midrange.com. | Questions should be directed to the list owner/operator: david@midrange.com +---
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2025 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].