  • Subject: Re: Host Print Transform Work Station Customizing Objects
  • From: James Turnbull <jamest@xxxxxxxxxxxxxxx>
  • Date: Tue, 09 Dec 1997 10:40:54 +1100
  • Organization: International Technology Group

Firstly you must end the writer before you can change the outq settings with the
CHGOUTQ command.  When you have ended the writer you can then change the
Manufactor Type and Model paremeter to *WSCST and define which object you use:

Manufacturer type and model  . . MFRTYPMDL      *WSCST
Workstation customizing object   WSCST          *HP4NEW
  Library  . . . . . . . . . . .                                    QGPL


After issuing the CHGOUTQ command on an ended writer the writer will restart 
with
the new settings.  Hope this helps.

                                                                        James
Turnbull
                                                                        AS/Tech
Consulting

Carol Collins wrote:

>  Vern,
>
>  You sent two answers to my message regarding changing the output queue to
>  use a new *WSCST object.  The first was:
>
>
>  >That change is done in the *DEVD.
>
>  And the second was:
>
> >More of the same: specify *WSCST in Manufacturer/model. Then a WSCST
> >parameter should appear.
>
>
>  Sorry to be so dense, but I still don't get it.  For one thing, I don't
>  have a device description for the remote print queue, so there is nothing
>  there to change.  And, when I use the WRKOUTQD or CHGOUTQ, only a few of
>  the parameters are allowed to be changed;  manufacturer/model is not one
>  of them.  But, I appreciate your attempt to clarify this for me.  If
>  you'd care to take another stab at it, I would be grateful.
>
>    -- Carol
>
>
>  +=======================================================================+
>  |    Carol Collins   Sr. Network Administrator                          |
>  |                    WASTREN  /  Holmes and Narver Services, Inc.       |
>  |                    2597 B-3/4 Road                                    |
>  |                    Grand Junction, CO  81503                          |
>  |                    U.S. Dept of Energy  Grand Junction Office         |
>  |    Internet:       Carol.Collins@doegjpo.com                          |
>  |    Phone   :       (970) 248-6524                                     |
>  +=======================================================================+
>
>
> +---
> | This is the Midrange System Mailing List!
> | To submit a new message, send your mail to "MIDRANGE-L@midrange.com".
> | To unsubscribe from this list send email to MIDRANGE-L-UNSUB@midrange.com.
> | Questions should be directed to the list owner/operator: david@midrange.com
> +---
> umidr



+---
| This is the Midrange System Mailing List!
| To submit a new message, send your mail to "MIDRANGE-L@midrange.com".
| To unsubscribe from this list send email to MIDRANGE-L-UNSUB@midrange.com.
| Questions should be directed to the list owner/operator: david@midrange.com
+---


As an Amazon Associate we earn from qualifying purchases.

This thread ...

Replies:

Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].

Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.