On Fri, Jan 25, 2002 at 11:41:24AM +0100, Mihael Knezevic wrote: > On 2002.01.25 08:41 Scott Klement wrote: > > > > Please check the value of your QINACTITV system value. From the > > AS/400, type: DSPSYSVAL SYSVAL(QINACTITV) > > > > This system value tells the AS/400 to disconnect users who have been > > inactive for a certain number of seconds. > > > > Good Luck! > > > i definitly need that luck, cause the value in QINACTITV is *NONE which > means there is no checking for not active interactive jobs. > > has someone any suggestions? You can check the parameters INACCTIMO and TIMMRKTIMO with command CHGTELNA. On my systems (V4R2, V4R3) both values are zero, and tn5250 works without problems. -- Esda Feinstrumpffabrik GmbH Frank Richter, Leiter EDV Hauptstr. 76, D-09392 Auerbach E-Mail: frichter@esda.com
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].