From: Eric Tubbs <eatubbs@email.com> > 0097.00 05 PIC X(04). > > This is the dump from running the program. > MCH1202 exception in program CHPT0404 in TUBBS at MI instruction number 006F > COBOL statement number 97. The key to successful debugging is the PAY ATTENTION to the error message and try to understand it. Start by READING it. Hmmm, it says statement 97, but sequence number 0097.00 (the PIC X(04)) is not executable, so maybe 97 is not the same as 0097.00... Hmmm, let's look at the listing to see if there is a clue as to what statement 97 is. Hmmm, it is a move of some number. Hmmm, that number must contain garbage (not valid packed number), Hmmm, and so it goes....
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].