I see so it cant be that an object that wants to backup is in use
you're
saying its for sure the tape issue?
On Sun, Feb 28, 2016 at 8:08 AM, Marc Rauzier <marc.rauzier@xxxxxxxxx>
wrote:
Le 28/02/2016 13:40, Hoteltravelfundotcom a écrit :
Cause . . . . . : Expected labels not found during end of fileThis is probably due to a previous backup error on the same tape. The last
processing
for file QSYSTAP in library QSYS on device TAP01.
file on the tape is not properly closed with the EndOfFile label, and
therefore (the last file) cannot be used. This error also prevents the tape
to receive further files.
Normally, you should be able to read the tape up to the not complete last
file.
If you want to use this tape for writing, you have to force writing
something in place of the not complete last file. Make sure to retrieve its
sequence number and run a save command with a small quantity of data (for
example SAVLIB LIB(QTEMP)) and with the proper sequence number. This will
clear the last file error, so that you can further use SEQNBR(*END).
--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list
To post a message email: MIDRANGE-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/midrange-l.
Please contact support@xxxxxxxxxxxx for any subscription related
questions.
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.