You have to pass the entire 40 characters all the time - that is why the suggestion to use a CMD front end works so well - it takes care of this.

You do not say how you are calling it - is it in a sbmjob or what - it sounds as if you might have a literal value instead of a variable in the parameters. When literals are used in a call, there is padding up to the first 32 characters - everything after that is whatever happened to be in memory at the time. So use variables in direct calls, or pad out the literal just as you did on the command line.

It can be instructive to put your RPG into debug and see what is coming in from various contexts.

HTH
Vern

At 02:07 PM 11/24/2006, you wrote:

I have a CL pgm calling an RPGLE pgm that expects two variables.

CALL       PGM(SFTP2UPS) PARM(&IFSDIR &IFSFIL)

The two variables created in the CL are defined as *char and len=40
which is the same as in the RPGLE pgm.

I know this works as the CL dump shows the variables at len 40 padded
with blanks on the right.

&IFSDIR                  *CHAR           40
'/xfer/Tst/Out/UPSscs/Pick'
61A786859961E3A2A361D6A4A361E4D7E2A283A261D78983
+26           'Ticket/        '
E389839285A3614040404040404040

&IFSFIL                  *CHAR           40
'TSTBR20061124114711.I1INP'
E3E2E3C2D9F2F0F0F6F1F1F2F4F1F1F4F7F1F14BC9F1C9D5
+26           'T00            '
E3F0F0404040404040404040404040

When I run the pgm from the command line with variables padded with
blanks the pgm works fine.

CALL PGM(SFTP2UPS) PARM('TEST1                                   '
'TEST1                                   '

When I run the pgm from my CL it fails.

Parameters passed on CALL do not match those required.
Error found on CALL command.
CPF0001 received by SFTP2UPS at 5500. (C D I R)
D
Function check. CPF0001 unmonitored by SFTP2UPS at statement 5500,
instruction X'003B'.

Jerry Draper




--
Jerome Draper, Trilobyte Software Systems, since 1976
iSeries, Network, and Connectivity Specialists -- iSeries, LAN/WAN/VPN
Representing WinTronix, Synapse, Netopia, HiT, and others .....
(415) 457-3431; www.trilosoft.com

--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list
To post a message email: MIDRANGE-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/midrange-l.


As an Amazon Associate we earn from qualifying purchases.

This thread ...

Follow-Ups:
Replies:

Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].

Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.