Willie, I put this on an 800 that was otherwise current before. I used the option 8, everything delayed. When the system did its restart over the weekend to apply them it was a dead duck. No TCP contact, twinax console would issue a CPF error for all logon attempts. DST would work but nothing else. Level 2 had me run a few things and then IPL from the A side in manual mode which worked OK. Then they had me IPL that way again but in dedicated mode and then in DST run a special "consolidation" function that took about five minutes. Then IPL again normal and everything ran OK. They said there was a certain, rare combination that caused this and I hadn't really missed or messed up anything. There was one PTF in each product that was damaged. Most I could do a SNDPTFORD to download and then LODPTF to fix them. However 3 of them were not available in any form other than CD or FTP CD image. Over 400MB so took a lot of time to download to image catalog but then everything was fine. Roger Vicker, CCP On 11/30/2005 12:47 PM, Willie J. Moore wrote: >We are going to apply cume 5298 this weekend. I would like to know if there >are any problems that anyone has ran into durning or afterwards appling the >cume. >Thanks, >William.... > > > >
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].