On 9/19/2016 10:38 AM, Jeff Young wrote:
Try using the AID byte in the workstation file status data structure.
What is the AID code for 'Field Exit'?
'Enter' is x'F1'
https://www.ibm.com/support/knowledgecenter/ssw_ibm_i_72/apis/dsm1f.htm
http://www.textfiles.com/bitsavers/pdf/ibm/525x/GA21-
9247-2_5250_Information_Display_System_Functions_
Reference_Manual_May80.pdf
(page 59)
I know I can request Field Exit Required on the FFW, but I didn't
realise it was also available as an AID code.
On Thu, Sep 15, 2016 at 2:05 PM, p.Caroti <p.caroti@xxxxxxxx> wrote:
I have a display with a field the CHECK(ER) Keyword (Automatic Record
Advance); Is it possible to understand if Enter or Field exit has been
pressed ?
--
--buck
Visit wiki.midrange.com and register for an account. Edit a page that
helps you, and because it's public, you'll help someone else, too!
--
This is the RPG programming on the IBM i (AS/400 and iSeries) (RPG400-L)
mailing list
To post a message email: RPG400-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/rpg400-l
or email: RPG400-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/rpg400-l.
Please contact support@xxxxxxxxxxxx for any subscription related
questions.
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.