I haven't done much with the AID byte for CHECK(ER) fields, but
according to the documentation Field Exit on a CHECK(ER) field should be
returning X'3F', while Enter should return X'F1'.

Joe

> From: Bob O.
> 
> I have a program I am working on where a field has CHECK(ER) assigned.
> The
> users want to use the Enter key to page through the screens.  When the
> user(s) press the Field Exit (+ key on the numeric keypad) on the
> keyboard,
> the program checks for a valid ticket number.  If it is a valid
number,
> the
> program then positions the cursor to the next field via the CSRLOC
> keyword.
> When the Field Exit key is pressed however, the program is moving on
to
> the
> next screen instead of positioning to the next field.
> 
> I think what would solve the problem is checking for the hex code for
the
> field exit key.  I cannot find the hex value of the key in any of the
> books
> I have.  They all only show X'3F' for Auto Enter and X'F1' for Enter.
Is
> there a value for the field exit(+) key?


As an Amazon Associate we earn from qualifying purchases.

This thread ...

Follow-Ups:
Replies:

Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].

Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.