I'm setting on *in51 and *in52, turning off *in53, setting POSITIONAT=1, and
EXFMT'ing the control record, as follows:
C Eval *IN51=*ON
C Eval *IN52=*ON
C Eval *IN53=*OFF
C Eval PositionAt=1
C Write Footer
C ExFmt RaccSFC
The record I previously wrote to the subfile show up on the screen, and I
can scroll to the very bottom without problems. But when I press Enter, I
get the CPF5218 error on the EXFMT opcode statement line.
<clip>
It depends on what the program is doing when enter is pressed. The message
indicates the POSITIONAT field contains either 0 or a number that is greater
than the number of records in the subfile.
</clip>
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2025 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].