I would recommend: HCvtOpt(*DATETIME) D Time_Current S T D Date_Current S D DATFMT(*ISO) D Time_CurrentN S 6S 0 D Date_CurrentN S 8S 0 C Time Date_Current C Time Time_Current C move Date_Current Date_CurrentN C move Time_Current Time_CurrentN Now you can calculate woth date-fields, use the nummeric once etc. The layout is always CCYYMMDD Good luck, Henk Schipper. -----Original Message----- From: rpg400-l-admin@midrange.com [mailto:rpg400-l-admin@midrange.com]On Behalf Of leszek.gruszczynski@big.pl Sent: Thursday, 18 July, 2002 12:05 PM To: rpg400-l@midrange.com Subject: Re: TIME opcode to 14.0 field: how determine or change date format? Hi Try this D TimStmp S Z INZ C TIME TimStmp - You have date in iso format Then You may change date format after substring from TimStmp by move command. Regards Leszek Gruszczynski _______________________________________________ This is the RPG programming on the AS400 / iSeries (RPG400-L) mailing list To post a message email: RPG400-L@midrange.com To subscribe, unsubscribe, or change list options, visit: http://lists.midrange.com/cgi-bin/listinfo/rpg400-l or email: RPG400-L-request@midrange.com Before posting, please take a moment to review the archives at http://archive.midrange.com/rpg400-l.
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].