The number of parameter in the PI must equal the number in the PR. In your case, it does not. In fact, I do not see the PR section in your example. Denis Robitaille Directeur services techniques Cascades Inc 819 363 5187 fax 819 363 5177 >>> kflournoy@mks.com 09/07/00 03:58pm >>> To All Users, I am a newby to RPGILE and I am trying to write a subprocedure but I keep getting an error during the compile which states "RNF3765 30 a 000800 Not enough parameters specified in the procedure interface". How do you specify parms in a PR? +D PR_RdStin 1024 +D PR_RcvRec 1024 +D PR_RcvLen 9B 0 +D PR_RcvRecLen 9B 0 P #RdStin B *_________________________________________________________ D #RdStin PI D RcvRec 1024 > aaaaaaaaaaaaaaa 65 30 a 000800 Not enough parameters specified in the D RcvLen S 9B 0 D* D RcvRecLen S 9B 0 +--- | This is the RPG/400 Mailing List! | To submit a new message, send your mail to RPG400-L@midrange.com. | To subscribe to this list send email to RPG400-L-SUB@midrange.com. | To unsubscribe from this list send email to RPG400-L-UNSUB@midrange.com. | Questions should be directed to the list owner/operator: david@midrange.com +---
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].