Small problem, is this the answer? Program A, writes a record to the order detail file using logical LL0001LA. Program A, then immediately calls program B, which is passed the order number to recalculate the total order amount in the detail file to update the order header file. Program B uses a different logical, LL0001LB, over the order detail file. Program B, does a CHAIN to the first record for the order, then a subsequent READE until end of order. QUESTION??? Where is the pointer sitting when Program B does its first CHAIN to the order detail file LL0001LB? Is it where the last record was written or where? Thanks for your help. Lewis Lewis Libman llibman@behr.com 714 545 7101 x2118 +--- | This is the RPG/400 Mailing List! | To submit a new message, send your mail to RPG400-L@midrange.com. | To subscribe to this list send email to RPG400-L-SUB@midrange.com. | To unsubscribe from this list send email to RPG400-L-UNSUB@midrange.com. | Questions should be directed to the list owner/operator: david@midrange.com +---
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].