× The internal search function is temporarily non-functional. The current search engine is no longer viable and we are researching alternatives.
As a stop gap measure, we are using Google's custom search engine service.
If you know of an easy to use, open source, search engine ... please contact support@midrange.com.



Roberto,

With SCSI disks there will be stripes created depending on the number of disks in the set to start.

Total 07x 070
Disks Disks Disks
3 2 1
4 4 0
5 4 1
6 4 2
7 4 3
8 8 0
9 8 1
10 8 2
etc.

So if you always started with 4 or 8 disks you won't see any 070's until you add more but if you start with an odd number you'll always see at least one 070.

With SAS disks you will only see 070s when disks are added to an existing RAID set.

- Larry "DrFranken" Bolhuis

www.frankeni.com
www.iDevCloud.com
www.iInTheCloud.com

On 6/4/2013 10:43 PM, Roberto José Etcheverry Romero wrote:

Doctor, i've never seen a model 070 disk, i always see 072 or 074 disks, i
think the only way to get a 070 disk is to add a disk to an already created
raidset, so it doesnt redistribute parity like when starting from scratch,
I'll check tomorrow (have to continue rebuilding that 520 with the busted
loadsource), but in any case, extremely good to know that 070 model disks
could be drained may be a reason to invest the time in making a raidset
and then adding the last disk...

Best Regards,



On Tue, Jun 4, 2013 at 10:54 PM, DrFranken <midrange@xxxxxxxxxxxx> wrote:

Maybe.

At least one of the drives will be a model -070. This indicates that the
drive does not contain any parity data. So that's the one you want to
drain. This much will work for sure.

Now you need to select this drive and remove from parity protection.
Theoretically this will work because the drive doesn't contain any data
so only the other 7 drives need to be updated.

*HOWEVER* do not be surprised if the system says NO to this because with
a drive down the RAID set could be somehow 'locked'.

Assuming that completes, then use concurrent maintenance and remove it
from the system. Next use concurrent maintenance to remove the 'dead'
drive and put the removed one in it's place.

Now rebuild the data. And you win.

- Larry "DrFranken" Bolhuis

www.frankeni.com
www.iDevCloud.com
www.iInTheCloud.com

On 6/4/2013 11:14 AM, Roger Vicker, CCP wrote:
I am trying to salvage an old system on V5R4 using Raid5 on nine disk
drives.

Disk Unit 1 has failed. I want to remove Disk Unit 9 from the pool
(moving data off) and remove it from the Raid Set. Then use it to
replace the failed Unit 1.

I have only been able to find online documentation on doing this with
iSeries Navigator. However, the copy I have does not show anything under
<Configuration><Hardware><Disk Units>. Can this be done with just SST
(and maybe DST) and if so would someone mind posting a link.

Thanks

Roger Vicker, CCP

--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list
To post a message email: MIDRANGE-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/midrange-l.



As an Amazon Associate we earn from qualifying purchases.

This thread ...

Replies:

Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].

Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.