There were thousands and thousands of repeats of the job in the list
below:
WRKACTJOB OUTPUT(*PRINT) JOB(QZRCSRVS)
By using NETSTAT IBM and I were able to tie it in from loopback
(127.0.0.1) and one remote port to one local port used by QYPSJSVR or
Management Central.
The QZRCSRVS people expect the job that uses them to say "I am done."
Apparently MGTC says that's for the little people. Instead MGTC just
processes another request and spawns another prestart job and leaves the
old one hanging.
Work around: Issue ENDTCPSVR *MGTC and wait until they all end. Now, it
takes awhile to end 16,000+ jobs (like one lpar). When done, you can
issue STRTCPSVR *MGTC.
Oh, and we last IPLed June 12. I wonder how many we would have had
otherwise?
One APAR said they might fix this in some future release and just accept
the work around. (See also "reach around".) Some other apar said they're
working on a test ptf.
Rob Berendt
--
Group Dekko Services, LLC
Dept 01.073
Dock 108
6928N 400E
Kendallville, IN 46755
http://www.dekko.com
--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list
To post a message email: MIDRANGE-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/midrange-l.
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.