James,
Can't think of any reason. Since many of our files still use the S/36 group naming convention, I have a library for compiles that is simply CRTDUPOBJ's of those files without the group identifier. I've never had a problem later running the program against the real (A.whatever) file.
My considered conclusion is that something, unbeknownst to you, has changed in the file since the program was compiled. Or it may have picked up another file of the same name (but different attributes) during the compile, which would be a library list issue.
Jerry C. Adams
IBM System i Programmer/Analyst
B&W Wholesale
office: 615-995-7024
email: jerry@xxxxxxxxxxxxxxx
-----Original Message-----
From: midrange-l-bounces@xxxxxxxxxxxx [mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of James Lampert
Sent: Wednesday, November 05, 2008 10:57 AM
To: Midrange Systems Technical Discussion
Subject: Unexplained level check problem
Anybody know of a reason why one would get a level check error on a file
that looks identical to the one you were compiled for, and was created
either with a CRTDUPOBJ of that file, or was compiled from the same source?
--
James H. H. Lampert
Touchtone Corporation
--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list
To post a message email: MIDRANGE-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit:
http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at
http://archive.midrange.com/midrange-l.
As an Amazon Associate we earn from qualifying purchases.