|
Colin, Ok, I thought you had a time when you did a wrkobjlck and so it locked. Perhaps I misunderstood. It's kind of hard to recreate what was in place so I am making some assumptions: 1.) You are monitoring the OUTQ OPTIO - well at least whoever set this up before was.... :-) 2.) The merge is based on job information (ie the monitor program is making the selection based on job name information) 3.) I think the older libraries (FX300 or whatever) are actually left over from when the product was upgraded to the OPTIO DCS version 5. So, I don't think they are involved or causing anything. Again, these are assumptions. Generally speaking the setup is easy (I hate to admit it but I'm trying to find our manuals/CD's - redesigning the data center has caused me more lost documents and cd's than I care to mention). The heirarchy is as follows: 1.) Create a group - in this case I'm assuming yours is US. Or is one of them. 2.) Tell which OUTQ you are monitoring. 3.) The command to find, merge, and send the checks to their target (MRGCHKSDM) Items 1 and 2 are really just designed to make sure that you have a unique job/job name for each outq you want to monitor. I would assume that part of this process (#2) would create the dtaq (and dtaara) and attach it to the outq you are monitoring. Checking on items 1 and 2 (go fxmain, option 5 utilities, option 17 monitor output queues, then menu options 1 and 2) you should see a group called US and then a output queue of optio. If you have these items and no dtaq then it seems like it was deleted.....or something similar. So best I can suggest now is to check your config, confirm the existance of the dtaq, and the parm on the output queue If the dtaq does not exist you could create it manually into optiofile and change the output queue if necessary. That's the best I can suggest at this time. ________________________________ From: midrange-l-bounces@xxxxxxxxxxxx on behalf of Colin.Swain@xxxxxxxxxxx Sent: Wed 3/15/2006 9:53 AM To: midrange-l@xxxxxxxxxxxx Subject: Re: Optio Cheque Printing Thanks Mike, I get the error message when I Start Monitoring Output Queue. I don't even know if Start Monitoring Output Queue is the correct action to get this working - does it need to be started in order for the formatting process to work? When I try the WRKOBJLCK OBJ(*LIBL/OPTIOUS) OBJTYPE(*DTAQ) I get the following message: Additional Message Information Message ID . . . . . . : CPF0939 Severity . . . . . . . : 30 Message type . . . . . : Information Date sent . . . . . . : 15/03/06 Time sent . . . . . . : 11:06:45 Message . . . . : Object OPTIOUS type *DTAQ was not found in library OPTIOFILE. Recovery . . . : Correct the object name, the object type, or change the library name (OBJ parameter). Then try the request again. Any idea of anywhere else can I see what job information it is trying to match? Or do I have a missing object? Does anyone have OptioDCS documentation they can send me so that I can better understand the whole process? Thanks Col ----- Message from "Crump, Mike" <Mike.Crump@xxxxxxxxxxxxxxxx> on Tue, 14 Mar 2006 16:08:50 -0500 ----- To: "Midrange Systems Technical Discussion" <midrange-l@xxxxxxxxxxxx> Subject: RE: Optio Cheque Printing Colin, The mrgchksdm command takes a source file, merges it with a defined check form, and sends it to a target queue. The fx300 stuff is left over from the xpoint days so I'm not sure if that is causing your problem or not. The OPTIOUS should most likely be the DATAQ used by the monitoring program. If it is in use it should be by the job that has historically been used as the monitoring job. At least that is my guess. When you get the error message are you getting it when you attempt to run the merge in a different manner? If the monitoring program is in place it should grab anything that matches the parms in the mrgchksdm command. The parm merge type indicates that you are doing a match on job information. In our case we do it based on form. Different way of getting to the same spot. If you are putting something in the outq and not getting a result it would most likely be that you are not getting a match on your job information. If you do a wrkobjlck on the OPTIOUS DTAQ - that should point you to the job - you can check the job log. Granted it tends to put a lot of *&^% out there but it can give you some further ideas. Your check form also allows you to remap your data (move it, resize it, change font, etc.). -----Original Message----- From: midrange-l-bounces@xxxxxxxxxxxx [mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Colin.Swain@xxxxxxxxxxx Sent: Tuesday, March 14, 2006 11:56 AM To: midrange-l@xxxxxxxxxxxx Subject: Fw: Optio Cheque Printing Apologies to all for not putting the correct Subject line in the previous email (see below) - bit of a D'oh on my part, if anyone didn't read it because of the ambiguous nature of the Subject line, please give it a second chance. Moving, on I tried taking option 4. Start Monitoring Output Queue from the Monitor Output Queues menu and I get the following message: Additional Message Information Message ID . . . . . . : CPA0701 Severity . . . . . . . : 99 Message type . . . . . : Inquiry Date sent . . . . . . : 14/03/06 Time sent . . . . . . : 16:29:00 Message . . . . : CPF9801 received by XPMN3BCL at *N. (C D I R) Cause . . . . . : Control language (CL) program XPMN3BCL in library OPTIO detected an error at statement number *N. Message text for CPF9801 is: Object OPTIOUS in library OPTIOFILE not found. Recovery . . . : This inquiry message can be avoided by changing the program. Monitor for the error (MONMSG command) and perform error recovery within the program. To continue, choose a reply value. Possible choices for replying to message . . . . . . . . . . . . . . . : C -- Cancel the CL program. D -- Dump the CL program variables and cancel the CL program. I -- Ignore the failing command. R -- Try the failing command again. Type reply below, then press Enter. Reply . . . . Any ideas if this means that there is a missing formatting file (OPTIOUS)? It is a bit strange because when I do: WRKOBJ OBJ(*ALL/OPTIOUS) the object is in the OPTIOFILE library, but it says it is in use. Thanks Col ----- Forwarded by Colin Swain/London/V2 Music on 14/03/2006 16:27 ----- Colin Swain/London/V2 Music 14/03/2006 15:32 To midrange-l@xxxxxxxxxxxx cc Subject Re: MIDRANGE-L Digest, Vol 5, Issue 564 Thanks Mike, I have sent Optio an email, let see how long they will take to get back to me, I guess this documentation may be hard to come by. CKMAIN is not in the OPTIO library, I find it in FX300. Is this the older (XPOINT) version? I can get to FXMAIN, however the description in the top left corner XMAIN2, not an issue I suppose. I have taken a look at "Monitor Output Queues", going to 3. Work with Commands to be Processed, I find that there is the following: Unique ID and Description. Unique ID Type . . . . . FT Unique ID. . . . . . . . APCHECKS Output Queue . . . . . . OPTIO Library . . . . . . . . . *LIBL Description. . . . . . . MERGE US CHECKS Command. MRGCHKSDM NAME(CV2US) MRGTYP(*JOB) FILE(£FILE) JOB(£JNUM/£USER/£JOBN) SPL NBR(9999) TOUTQ(V2UKPRT4) RPCNST(B) This command doesn't make sense as there is no V2UKPRT4. I tried to change it to the printer in front of me (V2UKFIN1) and run a cheque through. I have been told by the AP girl in New York that she used to change the output queue to OPTIO and the cheques would print. This was the command I used: CHGSPLFA FILE(S04572) JOB(784971/UKCXS30/QPADEV0026) OUTQ(OPTIO) However, nothing happened. I am just guessing that this should work. Can anyone point me in the direction of understanding what the above embedded Command does? The problem is that the output is in landscape when it should be portrait and is way too small, I have tried fiddling around with the Printer File Settings for S04572 with only minimal success (either increasing the text size or changing the page rotation - not both). Thanks Col -----Original Message----- From: midrange-l-bounces@xxxxxxxxxxxx [mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Mike.Crump@xxxxxxxxxxxxxxxx Sent: Tuesday, March 14, 2006 6:11 AM To: midrange-l@xxxxxxxxxxxx Subject: RE: Optio Cheque Printing Colin, We use the CheckBook portion of the Optio software also. In our case it was part of the OptioDCS package that we originally picked up when it was XPoint. If you go to the web site it might be very hard to find what you need (www.optiosoftware.com). However, from there you can get a tech support number and email (custcare@xxxxxxxxxxxxxxxxx). Based on your location you might want to try the European location: Optio Software UK Ltd. Blythe Valley Park Shirley - Solihull West Midlands B90 8AD United Kingdom tel: +44 (0)121 506 9640 fax: +44 (0)121 506 9641 e-mail: info-uk@xxxxxxxxxxxxxxxxx Directions Generally speaking you should be able to access what you need via the menu CKMAIN (that should be in the library OPTIO). We monitor our output queues which is accessible off of the FXMAIN menu and under utilities (opt 5) and monitor output queues (opt 17). Part of what I'd like to know is what do you mean by it's not working....nothing happening, output incorrect, etc. -----Original Message----- From: midrange-l-bounces@xxxxxxxxxxxx [mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Colin.Swain@xxxxxxxxxxx Sent: Tuesday, March 14, 2006 6:11 AM To: midrange-l@xxxxxxxxxxxx Subject: Optio Cheque Printing Hi all, We appear to have Optio software running on our AS/400 that was previously formatting cheques from JDE. However, there have been some office moves and either the software is no longer working or the configuration is incorrect for the new printers. I have looked around on our system and found the Optio library, which was created on 16/06/98, however I cannot find any documentation on how to use and configure the software. The library description is Optio 5.0.1a Distribution Library-RISC. Any help greatly appreciated Col ================================ Colin Swain Systems Accountant V2 Music Group 131 Holland Park Avenue London W11 4UT Tel: +44 (0) 20 7471 3089 Fax: +44 (0) 20 7471 3060 ______________________________________________________________________ This email has been scanned by the MessageLabs Email Security System. For more information please visit http://www.messagelabs.com/email ______________________________________________________________________ -- This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list To post a message email: MIDRANGE-L@xxxxxxxxxxxx To subscribe, unsubscribe, or change list options, visit: http://lists.midrange.com/mailman/listinfo/midrange-l or email: MIDRANGE-L-request@xxxxxxxxxxxx Before posting, please take a moment to review the archives at http://archive.midrange.com/midrange-l.
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.