> >>If I remember right, from my own experiences some years ago, a *USER to >> *OWNER conversion doesn't seem to require observable information on a >> CISC box, >> >> > No, this is correct, however, i believe that the requirement of having > the observable info only came with V5.1 and not with RISC. No, that wouldn't be the case, because I couldn't have made the observation if it were: our RISC boxes are on V4R2, V4R4, and V4R5. We don't have a V5 box as of yet. We've never needed one. If we end up having to ship a separate QV version for V5 that doesn't fail installation on high object-restoration-security settings, we'll burn that bridge when we get to it. -- JHHL
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2025 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].