Glen,
Running V5R2M0 and at cume C3364 with the latest group & hipers installed
the end of January.
TL03364 is the ptf (cume C3364)
Here is what WRKPTFGRP displays:
Opt PTF Group Level Status
SF99519 90 Installed
SF99502 11 Installed
SF99169 15 Installed
SF99039 2 Installed
Thanks - Dennis.
Dennis Munro
"I love deadlines. I especially like the whooshing sound they make as they
go flying by."
Dilbert's Words Of Wisdom
Badger Mining Corporation
www.badgerminingcorp.com
dmunro@xxxxxxxxxxxxxxxxxxxx
(920) 361-2388 Ext.141
-----Original Message-----
From: Orsburn, Glen O [mailto:orsburn@xxxxxxxx]
Sent: Tuesday, February 17, 2004 9:17 AM
To: Midrange Systems Technical Discussion
Subject: RE: SQL System Error
Dennis,
What release and ptf do you have?
Glen
-----Original Message-----
From: midrange-l-bounces@xxxxxxxxxxxx
[mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Dennis Munro
Sent: Tuesday, February 17, 2004 9:07 AM
To: 'Midrange Systems Technical Discussion'
Subject: RE: SQL System Error
Low & behold I still had the premiere database on my system & I ran the
statement as you have it coded & it ran just fine. The columns names
have changed & the data has been refreshed but other than that the
statement ran as you had coded it.
Thanks - Dennis.
Dennis Munro
"I love deadlines. I especially like the whooshing sound they make as
they go flying by." Dilbert's Words Of Wisdom
Badger Mining Corporation
www.badgerminingcorp.com
dmunro@xxxxxxxxxxxxxxxxxxxx
(920) 361-2388 Ext.141
-----Original Message-----
From: Orsburn, Glen O [mailto:orsburn@xxxxxxxx]
Sent: Tuesday, February 17, 2004 8:35 AM
To: Midrange Systems Technical Discussion
Subject: SQL System Error
ny suggests or help on this one would be appreciated:
When we run subquery interactively in SQL this is the error: (if I
should run each Select statement by it self no error occurs)
<<Picture (Metafile)>> SELECT customer_num, customer_name
FROM premiere/customer
WHERE customer_num in (select customer_num from premiere/orders where
order_date = '10/20/2003')
I'm getting the following error when we run a interactive SQL statement
above:
Message ID . . . . . . : SQL0901 Severity . . . . . . . : 50
Message type . . . . . : Diagnostic
Message . . . . : SQL system error.
Cause . . . . . : An SQL system error has occurred. The current SQL
statement cannot be completed successfully. The error will not
prevent
other SQL statements from being processed. Previous messages may
indicate
that there is a problem with the SQL statement and SQL did not
correctly
diagnose the error. The previous message identifier was CPF4204.
Internal
error type 3109 has occurred. If precompiling, processing will not
continue
beyond this statement.
When I dig in a little deeper it has the following message:
System object ORDERS ORDERS partially damaged. Internal dump ID .
Error
class 0, device number X'0000'.
Internal failure occurred in query processor.
File QAP0ZDMP created in library QTEMP.
Member QP0Z110085 added to file QAP0ZDMP in QTEMP.
User Trace data for job 110085/GOSQL225/QPADEV000D dumped to member
QP0Z110085 in file QAP0ZDMP in library QTEMP.
27 records copied from member QP0Z110085.
1 User Trace buffer(s) deleted.
SQL system error.
Glen
FVTC Instructor
"Give a man a fish and he'll eat for a day. Teach a man to fish and
he'll eat for a lifetime.".
_______________________________________________
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing
list To post a message email: MIDRANGE-L@xxxxxxxxxxxx To subscribe,
unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/midrange-l.
The information contained in this e-mail message is confidential
information intended only for the use of the individual or entity named
above. If the reader of this message is not the intended recipient, or
the employee or agent responsible to deliver it to the intended
recipient, you are hereby notified that any dissemination, distribution
or copying of this communication is strictly prohibited. If you have
received this communication in error, please immediately notify us by
telephone, and return the original message to us at the below address
via the U.S. Postal Service, and delete it from your computer. Badger
Mining Corporation P.O. Box 328 Berlin, WI 54923 920-361-2388
_______________________________________________
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing
list To post a message email: MIDRANGE-L@xxxxxxxxxxxx To subscribe,
unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/midrange-l.
_______________________________________________
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list
To post a message email: MIDRANGE-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/midrange-l.
The information contained in this e-mail message is confidential information
intended only for the use of the individual or entity named above. If the
reader of this message is not the intended recipient, or the employee or
agent responsible to deliver it to the intended recipient, you are hereby
notified that any dissemination, distribution or copying of this
communication is strictly prohibited. If you have received this
communication in error, please immediately notify us by telephone, and
return the original message to us at the below address via the U.S. Postal
Service, and delete it from your computer. Badger Mining Corporation P.O.
Box 328 Berlin, WI 54923 920-361-2388
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2025 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.