|
Congrats Rob ! So how long did access path rebuilds take ? I was telling a friend about this and he said they had problems with the power supplies in their 820-24 way (or is that 12 ? Can't remember). It has 3 and when one was replaced it crashed the system. When it came back up, it reported another was bad - i.e. misreporting... They were told this was a known problem and forget concurrent maintenance - the recommended path was powering down the system and replacing all of them at once... Chuck -----Original Message----- From: midrange-l-admin@midrange.com [mailto:midrange-l-admin@midrange.com]On Behalf Of rob@dekko.com Sent: Wednesday, August 14, 2002 1:24 PM To: midrange-l@midrange.com Subject: RE: Lovely: Our 840 12-way is down. This is a multipart message in MIME format. -- [ Picked text/plain from multipart/alternative ] The 840 is up, kind of. Came back up around midnight:30 last night. The new AC module is working fine. We have a bad power supply still. Maybe we'll replace that this weekend. It's redundant. Evidently the spike from the 400 kicked off a little something on the UPS also. Just a simple reset of that particular item (didn't affect any other equipment - no additional downtime on our other iSeries, etc), and it's fine. Data seems fine. Some application record locks, but nothing OS related. Rob Berendt -- "They that can give up essential liberty to obtain a little temporary safety deserve neither liberty nor safety." Benjamin Franklin rob@dekko.com Sent by: midrange-l-admin@midrange.com 08/13/2002 11:01 PM Please respond to midrange-l To: midrange-l@midrange.com cc: Fax to: Subject: RE: Lovely: Our 840 12-way is down. IPL is still in progress. Storage Management didn't take too long. Context Rebuild has been running for over 57 minutes though. Rob Berendt -- "They that can give up essential liberty to obtain a little temporary safety deserve neither liberty nor safety." Benjamin Franklin rob@dekko.com Sent by: To: midrange-l@midrange.com midrange-l-admin@mi cc: drange.com Fax to: Subject: RE: Lovely: Our 840 12-way is down. 08/13/2002 09:57 PM Please respond to midrange-l They're still working on it. Had to replace an AC module. After that got replaced a power supply notified us that it was bad. In theory we can run without that power supply, it can be replaced concurrently, and it will be another 4 hours if they rush one in. We're going to run 'bareback'. They had this power supply on order to be drop shipped to us at 8am tomorrow anyway. So Dave will be back in 10 hours. He'll leave after the IPL completes and get's checked out. Rob Berendt -- "They that can give up essential liberty to obtain a little temporary safety deserve neither liberty nor safety." Benjamin Franklin "Walden H. Leverich" To: "'midrange-l@midrange.com'" <midrange-l@midrange.com> <WaldenL@techsoftin cc: c.com> Fax to: Sent by: Subject: RE: Lovely: Our 840 12-way is down. midrange-l-admin@mi drange.com 08/13/2002 05:39 PM Please respond to midrange-l Rob, Please let us know when you're back up. -Walden ------------ Walden H Leverich III President Tech Software (516) 627-3800 x11 (208) 692-3308 eFax WaldenL@TechSoftInc.com http://www.TechSoftInc.com Quiquid latine dictum sit altum viditur. (Whatever is said in Latin seems profound.) -----Original Message----- From: rob@dekko.com [mailto:rob@dekko.com] Sent: Tuesday, August 13, 2002 17:24 To: midrange-l@midrange.com Subject: Lovely: Our 840 12-way is down. Had our 840-12 way drop unexpectedly. 11 - A6xx 0255 12 - 0DB0 0062 0001 0002 2505 8100 0019 1000 13 - 0000 0120 0019 1000 2843 0000 B600 6973 This is a 6 tower system. One of the towers has no lights on any of it's panels. It has no lights on any of it's power supplies. We had our electrician check the outlet. It is good. We called software. They quickly determined it was hardware and stayed on the phone until hardware had all the information they needed. We've IPLed up to DST and have 3 failing part numbers SIIOADP LOOP# 257 - HSL I/O BRIDGE 04N5508 NETWORK INTERFACE CONTROLLER SIRGCBL LOOP#257 - HSL CABLE OR CONNECTION Central had notified local, and gave them some suggested part numbers. Still waiting for news from the Fort Wayne office. Anyone seen the Weber brothers? Rob Berendt -- "They that can give up essential liberty to obtain a little temporary safety deserve neither liberty nor safety." Benjamin Franklin _______________________________________________ This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list To post a message email: MIDRANGE-L@midrange.com To subscribe, unsubscribe, or change list options, visit: http://lists.midrange.com/cgi-bin/listinfo/midrange-l or email: MIDRANGE-L-request@midrange.com Before posting, please take a moment to review the archives at http://archive.midrange.com/midrange-l. _______________________________________________ This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list To post a message email: MIDRANGE-L@midrange.com To subscribe, unsubscribe, or change list options, visit: http://lists.midrange.com/cgi-bin/listinfo/midrange-l or email: MIDRANGE-L-request@midrange.com Before posting, please take a moment to review the archives at http://archive.midrange.com/midrange-l. _______________________________________________ This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list To post a message email: MIDRANGE-L@midrange.com To subscribe, unsubscribe, or change list options, visit: http://lists.midrange.com/cgi-bin/listinfo/midrange-l or email: MIDRANGE-L-request@midrange.com Before posting, please take a moment to review the archives at http://archive.midrange.com/midrange-l. _______________________________________________ This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list To post a message email: MIDRANGE-L@midrange.com To subscribe, unsubscribe, or change list options, visit: http://lists.midrange.com/cgi-bin/listinfo/midrange-l or email: MIDRANGE-L-request@midrange.com Before posting, please take a moment to review the archives at http://archive.midrange.com/midrange-l. _______________________________________________ This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list To post a message email: MIDRANGE-L@midrange.com To subscribe, unsubscribe, or change list options, visit: http://lists.midrange.com/cgi-bin/listinfo/midrange-l or email: MIDRANGE-L-request@midrange.com Before posting, please take a moment to review the archives at http://archive.midrange.com/midrange-l.
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.