Curiouser and curiouser. On a hunch I changed the "field in error" to "1940-01-01" and executed the program. The SQL error disappeared. I then changed the value to "1939-12-31" and the SQL error reappeared. The field in question is a DATE field using the *ISO format. The documentation clearly states the valid values are between "0001-01-01" and "9999-12-31". So am I missing a PTF or misreading the documentation? Donald R. Fisher, III Project Manager The Roomstore Furniture Company (804) 784-7600 ext. 2124 DFisher@roomstoreeast.com
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].