QLMTDEVSSN was put in to replicate a mainframe function. If you want something more sophisticated, you need to do it in your own initial program. Al Al Barsa, Jr. Barsa Consulting Group, LLC 400>390 914-251-1234 914-251-9406 fax http://www.barsaconsulting.com http://www.taatool.com Laszlo Lorincz <laszlo.lorincz@bms To: MIDRANGE-L@midrange.com .com> cc: Sent by: Subject: Limit device session question midrange-l-admin@mi drange.com 09/25/01 07:25 AM Please respond to midrange-l Hi All, I have a problem with it. The QLMTDEVSSN system value set to 1. The LMTDEVSSN parameter is set to *SYSVAL in user profile. If the user has an active job, the system does not let the user in. It is fine. When the user has a disconnected job, the user can log on. It seems the system does not check the disconnected jobs. How can I solve this problem? Thanks Laszlo _______________________________________________ This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list To post a message email: MIDRANGE-L@midrange.com To subscribe, unsubscribe, or change list options, visit: http://lists.midrange.com/cgi-bin/listinfo/midrange-l or email: MIDRANGE-L-request@midrange.com Before posting, please take a moment to review the archives at http://archive.midrange.com/midrange-l.
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.