Place the following in you signon program: OVRPRTF FILE(*PRTF) HOLD(*YES) This OVRPRTF will take precedence over subsequent OVRPRTF's unless the latter specify SECURE(*YES). You could optionally specify OUTQ to redirect the output to a non-printing output queue if you want. Charles L.Massoglia, President Massoglia Technical Consulting, Inc. cmassoglia@voyager.net In MI 517-676-9700 or in NC 919-363-9395 ----- Original Message ----- From: "Condon, Mike, /m1c" <m1c@ingersoll-imc.com> To: <MIDRANGE-L@midrange.com> Sent: Friday, 03 August, 2001 15:57 Subject: Hold all printouts > We are working on a test/development system and would like for all > spooled output for certain signons to always be put on hold. However > in our CL programs there are overrides that say HOLD(*NO). Is there > a way to override these overrides in a CL program at login time? +--- | This is the Midrange System Mailing List! | To submit a new message, send your mail to MIDRANGE-L@midrange.com. | To subscribe to this list send email to MIDRANGE-L-SUB@midrange.com. | To unsubscribe from this list send email to MIDRANGE-L-UNSUB@midrange.com. | Questions should be directed to the list owner/operator: david@midrange.com +---
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].