|
Hi Folks, Had a weird one this morning. I'm at a new shop and the AS/400 here will be replacing a NCR/Unix box. I'm trying to get the AS/400 setup for "prime time". Have the daily backups in place and last night I thought I'd run a test IPL. I came in this morning and it appeared that all was well until I started checking around. CTL02 was vary on pending and varying it off and back on did nothing. I noticed that in QSYSOPR it was saying "Line resource name CMN0x not found" (the x being a number and 4 messages in total). Then I noticed that our 9427 tape unit was not available. I checked out WRKHDWRSC *CMN and saw the Comm Ports not operational and ditto for the 2809 controlling them. QSYSOPR showed NO errors (other than the Line resource name not found), WRKPRB had NO problems of ANY kind and the only errors under service tool were 6 5294 "BUFF" errors all at the SAME time earlier in the morning... I tried another IPL and got the same thing. I called Rochester and the guy had me check under Logical Hardware Resources on System Bus under SST and we had the System Bus, Multiple Function IOP 9164-001 and Multiple Function IOP 2809-001 and System Bus again and that was it. I'm new here and had not gotten around to documenting what was what, etc. (came from a 530 & 500 shop...) so I wasn't sure what it should show (Am NOW !!! <BG>). I hit an F10 for "Non-reporting resource" and a list came up with a 2809 on it, a bunch of CMN's and the tape drive. He said it was OK to blow those away and I said "are you SURE" and he said yes and I did. He then had me try an I/O IPL for the 2809 and that started and after 10 minutes, he said he would get a CE on-site to CONFIRM the configuration, etc. because it shoulldn't take that long. The CE got here and the reset was still going (not) after about 2 hours at this point. Per Rochester I did an ENDJOB on the job which was running on the console, did an ENDJOBABN and eventually we had to force power down. We came up in DST and everything looked OK. We came on up and we had to tell the system what Card Position the CMN and Tape Unit were on (it had renamed them and dropped/detached the real ones...) and all is fine now. NO word on what happened. The guy in Rochester said they HAD seen something similar on V4R2 and there was a PTF (the system was "randomly" renaming Resources... WHAT a nightmare) but nothing for V4R1... ANYBODY heard of this or had this happen ? WHAT in the WORLD would/could cause it ? I NOW know that we have TWO 2809's - one in the main unit and one in the expansion unit... Thanks, Chuck +--- | This is the Midrange System Mailing List! | To submit a new message, send your mail to MIDRANGE-L@midrange.com. | To subscribe to this list send email to MIDRANGE-L-SUB@midrange.com. | To unsubscribe from this list send email to MIDRANGE-L-UNSUB@midrange.com. | Questions should be directed to the list owner/operator: david@midrange.com +---
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.